ADSM-L

ADSM V3 on MVS event routing

1998-05-28 17:21:19
Subject: ADSM V3 on MVS event routing
From: Julie Phinney <jphinney AT HUMANA DOT COM>
Date: Thu, 28 May 1998 16:21:19 -0500
Does anyone route event messages to the FILE receiver, then stop logging
once per day, spin the file off, and start logging again?
If so, have you found a way to do that with one job?
It seems the ADSM started task holds that file with DISP=OLD, so you can't
run a multi-step job against it where the 1st step stops the logging and
the 2nd step does a GENER to copy the file... because the job is checked
first for any datasets that are unavailable to ANY step.  So the job sits
and waits for the ADSM started task to release the dataset, which of course
won't happen until the first step of the job runs.
The only solution I can see is to run 2 separate jobs every day.
Has anyone else gotten around this?
Thanks!
Julie Phinney
JPHINNEY AT HUMANA DOT COM
<Prev in Thread] Current Thread [Next in Thread>