ADSM-L

Re: Problem labeling DLT on STK9714

1998-05-21 16:17:48
Subject: Re: Problem labeling DLT on STK9714
From: Claudia Masters <cmaster1 AT TUELECTRIC DOT COM>
Date: Thu, 21 May 1998 15:17:48 -0500
Check to see if you have outstanding replies:.
Q REQUEST
If so you must reply with the REPLY number:
REPLY nn




Mansoor Bajwa <Mansoor_Bajwa AT CPR DOT CA> on 05/21/98 09:43:27

Please respond to "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>

To:   ADSM-L AT VM.MARIST DOT EDU
cc:    (bcc: Claudia Masters/Texas Utilities)
Subject:  Problem labeling DLT on STK9714




Hello Luc,
     We had similar kind of problem on our STK9710 unit. Our current
environmet is ADSM version 2.1.15 for AIX.  There are two things that I
suggest you do,
1) label a tape without using the robotic arm, i.e just choosing the drive,
the command for that according to version2
will be:
     dsmlabel -drive=/dev/xxx,yyy -overwrite
where; xxx is the drive name i.e. mt0 or mt1
      yyy is the element number associated with the drive
ADSM should ask you to insert the tape in the drive.
NOTE: You will need the main door of STK9714 open
2) If step 1 works okay, then get the STK tech to turn "ON" the
fast load enable and then try again with your orignal procedure.
Hope this helps.
Mansoor Bajwa
Canadian Pacific Railway
Toronto Ontario
Mansoor_Bajwa AT cpr DOT ca
ORIGNAL MESSAGE
___________________________
Date:    Tue, 19 May 1998 21:16:00 +0200
From:    "Verellen, Luc" <lverelle AT JANBE.JNJ DOT COM>
Subject: Problem labeling DLT on STK9714
MIME-Version: 1.0
Content-Type: text/plain


     Hello,
     Installing ADSM V3 server on NT 4.0 system, attached to an STK9714
     (DLT7000, 2-drives) library.
     I entered a few cartridges into the robot.  When trying to label them,
     with GUI or command line " LABEL LIBVOL SEARCH=YES LABELSOURCE=BARCODE
     ....", the robot mounts the cartridge into the drive, but from then
     on, nothing seems to happen: no CPU consumption, no dismount, no mount
     of the next cartridge.
     Seems as if process is waiting for barcode label to be passed, or ...?
     Any ideas ?
     Best regards.
     Luc Verellen
     Janssen Pharmaceutica
     Beerse/Belgium
     (32)14/60.21.67
     lverelle AT janbe.jnj DOT com
<Prev in Thread] Current Thread [Next in Thread>