Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*Tape\s+Volume\s+States\s*$/: 3 ]

Total 3 documents matching your query.

1. Tape Volume States (score: 1)
Author: Rob Hefty <R.Hefty AT LABSAFETY DOT COM>
Date: Fri, 19 Nov 2004 12:31:12 -0600
Hello all How can a tape be listed in the volumes table as scratch and yet still have a value in the percent utilized column larger than zero? The tapes are old IBM 3575 format and the server is 5.1.
/usr/local/webapp/mharc-adsm.org/html/ADSM-L/2004-11/msg00614.html (10,407 bytes)

2. Re: Tape Volume States (score: 1)
Author: "Stapleton, Mark" <mark.stapleton AT BERBEE DOT COM>
Date: Fri, 19 Nov 2004 12:36:48 -0600
Details, please. Output of Q VOL <VOLUMENAME> F=D and Q LIBV <LIBRARYNAME> <VOLUMENAME> F=D would be illuminating. (A tape volume won't show up in the volume table as scratch; it would show up in the
/usr/local/webapp/mharc-adsm.org/html/ADSM-L/2004-11/msg00616.html (11,002 bytes)

3. Re: Tape Volume States (score: 1)
Author: Richard Sims <rbs AT BU DOT EDU>
Date: Fri, 19 Nov 2004 14:05:49 -0500
How can a tape be listed in the volumes table as scratch and yet still have a value in the percent utilized column larger than zero? ... The columns from Select output largely conform to the definit
/usr/local/webapp/mharc-adsm.org/html/ADSM-L/2004-11/msg00619.html (10,991 bytes)


This search system is powered by Namazu