- 1. Re: 100.0% full and still Filling? (score: 1)
- Author: Richard Sims <rbs AT BU DOT EDU>
- Date: Thu, 29 Dec 2005 09:11:47 -0500
- Wondering why the volume status is filling when the pct utilization is 100%? ... Why not? :-) I think the underlying problem is that the product is still using a single decimal position, which is in
- /usr/local/webapp/mharc-adsm.org/html/ADSM-L/2005-12/msg00496.html (11,023 bytes)
- 2. Re: 100.0% full and still Filling? (score: 1)
- Author: "Ochs, Duane" <Duane.Ochs AT QG DOT COM>
- Date: Thu, 29 Dec 2005 08:27:22 -0600
- I have seen this when the compression exceeds the predefined size of the volume. For instance a sdlt320 predefined at 160 and it actually holds more than that due to compression. Why not? :-) I think
- /usr/local/webapp/mharc-adsm.org/html/ADSM-L/2005-12/msg00497.html (11,346 bytes)
- 3. Re: 100.0% full and still Filling? (score: 1)
- Author: Jack Coats <Jack.Coats AT ARDENTHEALTH DOT COM>
- Date: Thu, 29 Dec 2005 08:45:43 -0600
- Yes it happens. Depends on what you specify when you specify tape capacity. I found that it would seldom go beyond 100% if you are using client compression, but will regularly go well beyond 100% if
- /usr/local/webapp/mharc-adsm.org/html/ADSM-L/2005-12/msg00499.html (11,809 bytes)
This search system is powered by