Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Veritas\-bu\]\s+Re\:\s+SCSI\s+reset\s+errors\s+and\s+downed\s+drives\s*$/: 3 ]

Total 3 documents matching your query.

1. [Veritas-bu] Re: SCSI reset errors and downed drives (score: 1)
Author: anthony.guzzi AT storability DOT com (anthony.guzzi AT storability DOT com)
Date: Wed, 5 Sep 2001 13:30:15 -0400
I've got one phrase for you: persistent binding I'm wondering if your bridges are being "discovered"/recognized in a different order then when NBU was installed. If you are using a fabric, then remem
/usr/local/webapp/mharc-adsm.org/html/Veritas-bu/2001-09/msg00033.html (13,246 bytes)

2. [Veritas-bu] Re: SCSI reset errors and downed drives (score: 1)
Author: scott.kendall AT abbott DOT com (scott.kendall AT abbott DOT com)
Date: Thu, 6 Sep 2001 17:37:18 -0500
Great information... I have just one question. What about NT/2000? I too have had the "DOWN" drive problem when a server is rebooted and for whatever reason doesn't see the drives in the correct orde
/usr/local/webapp/mharc-adsm.org/html/Veritas-bu/2001-09/msg00068.html (16,697 bytes)

3. [Veritas-bu] Re: SCSI reset errors and downed drives (score: 1)
Author: gyurchak AT veritas DOT com (Gregg Yurchak)
Date: Thu, 6 Sep 2001 23:51:48 -0400
I believe NT will always take the lowest WWN it receives off the switch it is plugged into and make it target 0, and then the next highest for target 1, and so on until it exhausts that switch, and t
/usr/local/webapp/mharc-adsm.org/html/Veritas-bu/2001-09/msg00075.html (17,436 bytes)