Upgrading to 7.4.5 (windows 2003) solved many nasty savegroup problems, but networker has been throwing this error whenever we load new tapes: nsrjb: RAP error: No jukeboxes are currently usable. The
Author: Francis Swasey <Frank.Swasey AT UVM DOT EDU>
Date: Tue, 8 Sep 2009 07:10:39 -0400
nsrjb: RAP error: No jukeboxes are currently usable. This is likely related to LGTsc09318. That fix makes NetWorker actually notice when the tape library goes into a "Not Ready" state. The original f
Thanks Frank. This only happens when I open the Mailbox door to deposit new tapes, we are using an ADIC Scalar 100 with three drives. Is there anyway I can make Networker realize when the doors are c
Author: Francis Swasey <Frank.Swasey AT UVM DOT EDU>
Date: Tue, 8 Sep 2009 09:23:28 -0400
Sami, It's been over a year since I was working with EMC on this issue. I have a Qualstar XLS library. There was one iteration of the code fix that did what you are describing. With that iteration of
Thanks again Frank, I am definitely talking to EMC about this one. Hanging savegroups in 7.4.4 were far better than this. I wonder if anyone else is going through this. -sami Sami, It's been over a y
Apologies for duplicating some info here. I load tapes manually into ADIC Scalar 100, it is directly attached via SCSI. Only the Networker server is connected to it (no dedicated storage nodes). The
Author: Rachel Polanskis <r.polanskis AT uws.edu DOT au>
Date: Wed, 9 Sep 2009 09:53:20 +1000
Thanks again Frank, I am definitely talking to EMC about this one. Hanging savegroups in 7.4.4 were far better than this. I wonder if anyone else is going through this. Hi, we are running 7.4.2 on a
Author: "HORWITZ, STANLEY R." <stan AT TEMPLE DOT EDU>
Date: Tue, 8 Sep 2009 22:09:19 -0400
If this issue occurs with any regularity, then why not just run "nsrjb -HH" via a crontab entry as a stop gap measure until a real solution is found by EMC? To sign off this list, send email to lists