Author: <Blane.Robertson AT capgeminienergy DOT com>
Date: Tue, 21 Aug 2007 11:07:55 -0500
NV 7.1.5 on AIX. Do rules that are in ESE.automation still get called if T/EC event forwarding is turned off? Peace, Blane Robertson Capgemini / Dallas Enterprise Systems Management/ Capgemini Energy
Yes. They are independent. ESE.automation is read by actionsvr on start up and he registers those rules, so each one should end in an Action. nvserverd runs the internal TEC adapter based on tecint.c
Author: <Blane.Robertson AT capgeminienergy DOT com>
Date: Tue, 21 Aug 2007 12:14:04 -0500
Never mind. I had never used ESE.automation before. I added a rule to it, but hadn’t received any events as of when I send the below. I got one to come through, and it is working fine. Thanks a
Yes. It is an independant mechanism. Event automation in general, as opposed to forwarding events to the tec. Rules in ESE.automation must not have a forward in them. So don't get them mixed up. Cord