From what I remember, the recommended catalog
backup was the hot backup when it first appeared (in 6.0?). I have
had to use it a couple of times with success every time.
Even if it could be dumped to disk and
transferred/mapped to the new system, it would be worth a try.
From:
"Justin Piszcz"
<jpiszcz AT lucidpixels DOT com>
To:
"'Shekel Tal'"
<Tal.Shekel AT uk.fujitsu DOT com>, "'Steve Quan'" <skq01 AT hotmail DOT com>,
<veritas-bu AT mailman.eng.auburn DOT edu>
Date:
03/16/2012 08:59 AM
Subject:
Re: [Veritas-bu]
Veritas-bu Digest, Vol 71, Issue 11
Sent by:
veritas-bu-bounces AT mailman.eng.auburn DOT edu
Hi,
I’ve gone from 32-bit to
64-bit with Linux on several occasions and did not have an issue; however
I’ve not tried that with Windows. Do you still have the old master
running? Have you tried using a hot catalog backup (cold backups
are deprecated anyhow)?
Justin.
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu]
On Behalf Of Shekel Tal
Sent: Friday, March 16, 2012 8:58 AM
To: Steve Quan; veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11
Did you try run bpclntcmd
prior to the upgrade?
I also noticed the 64 bit
and 32 bit change but wouldn’t have thought it would make a difference
Regards,
Tal Shekel
CSA
FUJITSU
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu]
On Behalf Of Steve Quan
Sent: 16 March 2012 12:54
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11
What seems to "stick out", is
the target OS is 64bit (vs the original 32bit OS) .... and the problem
only shows up after a "good" catalog restore ....
/Steve
---
> From: veritas-bu-request AT mailman.eng.auburn DOT edu
> Subject: Veritas-bu Digest, Vol 71, Issue 11
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Date: Fri, 16 Mar 2012 07:00:04 -0500
>
> Send Veritas-bu mailing list submissions to
> veritas-bu AT mailman.eng.auburn DOT edu
>
> To subscribe or unsubscribe via the World Wide Web, visit
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
> or, via email, send a message with subject or body 'help' to
> veritas-bu-request AT mailman.eng.auburn DOT edu
>
> You can reach the person managing the list at
> veritas-bu-owner AT mailman.eng.auburn DOT edu
>
> When replying, please edit your Subject line so it is more specific
> than "Re: Contents of Veritas-bu digest..."
>
>
> Today's Topics:
>
> 1. cold catalog recovery (Infantino, Joe (Contractor))
> 2. Re: cold catalog recovery (Shekel Tal)
> 3. Re: cold catalog recovery (Infantino, Joe (Contractor))
> 4. Re: cold catalog recovery (Infantino, Joe (Contractor))
>
>
> ----------------------------------------------------------------------
>
> Message: 1
> Date: Thu, 15 Mar 2012 16:38:58 -0400
> From: "Infantino, Joe (Contractor)" <JINFANTINO AT intersil DOT com>
> Subject: [Veritas-bu] cold catalog recovery
> To: <veritas-bu AT mailman.eng.auburn DOT edu>
> Message-ID:
> <13E204E614D8E04FAF594C9AA9ED0BB712D79E43 AT PBCOMX02.intersil DOT corp>
> Content-Type: text/plain; charset="us-ascii"
>
> We are trying to upgrade our NBU hardware and OS and are running into
> some issues that seem related to doing a cold catalog recovery and
name
> resolution.
>
> Current setup:
> Windows 2003 x86 SP2
> NBU 6.5.6
>
> New setup:
> Windows 2008 x64 SP2
> NBU 6.5.6
>
> Current server and new server are configured with the same name and
ip
> address.
>
> ISSUE:
> We can do a cold catalog backup and restore just fine but have a serious
> issue in the end. After both successes if we open the Activity Monitor
> we get an error - "Not connected, check if services are up."
>
> All service are up.
>
> bpjobsd log shows
>
> <2> job_connect: Can't connect automatically to client pbcobk01
status =
> 25 err = 10061
> <2> job_connect: Can't connect to client pbcobk01
> <16> main: Can't connect to pbcobk01 (46)
>
> We did a complete system rebuild, installed NBU 6.5.6, and configured
to
> write to disk. Test backup ran and Activity Monitor worked fine. Did
> the catalog recovery and the issue came back.
>
> I did some bpclntcmd tests and they all come back with the correct
name
> but the IP shows as 127.0.0.1. I added the hostname and real IP to
the
> hosts file with no luck.
>
> I tried the following tests:
> bpclntcmd -pn = correct short name with 127.0.0.1
> bpclntcmd -self = correct short name with 127.0.0.1
> bpclntcmd -hn pbcobk01 = correct short name with 127.0.0.1
> bpclntcmd -ip xxx.xxx.xxx.xxx = correct host and xxx.xxx.xxx.xxx for
ip
> address
>
> If I do these test on the current server they come back with the actual
> IP of the system.
>
> TIA
>
> Joe Infantino
> MCP, MCSA, Security+, ITILv3
> Senior Systems Analyst
> Security and Server Operations
> Intersil Corporation
>
> email: jinfantino AT intersil DOT com
>
> www.intersil.com
>
<<<snip>>>
Unless otherwise stated, this email has been sent from Fujitsu Services
Limited, from Fujitsu (FTS) Limited, or from Fujitsu Telecommunications
Europe Limited, together "Fujitsu".
This email is only for the use of its intended recipient. Its contents
are subject to a duty of confidence and may be privileged. Fujitsu does
not guarantee that this email has not been intercepted and amended or that
it is virus-free.
Fujitsu Services Limited, registered in England No 96056, registered office
22 Baker Street, London W1U 3BW.
Fujitsu (FTS) Limited, registered in England No 03808613, registered office
22 Baker Street, London W1U 3BW.
Fujitsu Telecommunications Europe Limited, registered in England No 2548187,
registered office Solihull Parkway, Birmingham Business Park, Birmingham,
B37 7YU._______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
"PLEASE NOTE: The preceding information may be confidential or
privileged. It only should be used or disseminated for the purpose
of conducting business with Parker. If you are not an intended
recipient, please notify the sender by replying to this message and
then delete the information from your system. Thank you for your
cooperation."
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Steve Quan
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Shekel Tal
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Justin Piszcz
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor)
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Justin Piszcz
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor)
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11,
scott . george <=
Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Martin, Jonathan
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Steve Quan
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor)
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Steve Quan
- Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor)
|
Previous by Date: |
Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor) |
Next by Date: |
Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Justin Piszcz |
Previous by Thread: |
Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Infantino, Joe (Contractor) |
Next by Thread: |
Re: [Veritas-bu] Veritas-bu Digest, Vol 71, Issue 11, Martin, Jonathan |
Indexes: |
[Date]
[Thread]
[Top]
[All Lists] |
|
|