If the resolutions are correct and you can ping the server then either bpcd
port 13782 is not listening or there is something such as client firewall or a
TCP wrapper blocking access to the port if you are not getting a bpcd log
generated.
Try this- telnet localhost 13782
Does that generate a bpcd log entry?
If not then try from <install path>netbackup/bin/type in bpcd. Does that
generate a log?
This link may help-
STATUS CODE 58: Can't connect to client. Troubleshooting procedures for status
58 errors
http://www.symantec.com/docs/TECH68832