Subject: Re: [Veritas-bu] SAN Switch Change caused NBU7 to lose tape drives
From: <judy_hinchcliffe AT administaff DOT com>
To: <VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU>
Date: Thu, 8 Jul 2010 21:49:53 +0000
Every time I have seen the -1 -1 -1 I had issues with the drive in NB and had 
to remove and read.
Always happened when something on the SAN went "a little wrong".

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu 
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Brandon35
Sent: Thursday, July 08, 2010 4:42 PM
To: VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU
Subject: [Veritas-bu] SAN Switch Change caused NBU7 to lose tape drives


Thanks for the info Judy,

Netbackup actually does not report any -1,-1,-1

I had only seen this in one of the Windows tape drive driver installers. One of 
my windows machines that is only seeing 5 of the 9 drives showed the first 5 
drives with normal bus, location, id numbers. but the last 4 drives showed as 
-1, -1, -1

 :?   i have no idea why

+----------------------------------------------------------------------
|This was sent by brandon.pawoll.ctr AT mda DOT mil via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu