Hi,

Please include the list in the future.
It appears you need to limit your labels to 6 characters.
Check the volume manager manual, you need to edit vm.conf for NBU 6.x++ 
the labels for LTOX should be no more than 6 characters long, if your 
barcode reader reads more than the first 6 characters, you need to limit 
it.

BTW, is this a new environment?
Or did this just start happening?
If it just started happening, have you run an inventory and retried the 
backup?

Justin.

On Tue, 13 Apr 2010, McDonald II, James F. wrote:

> Here is what I got when I ran the test:
>
> Opening {4,0,33,1}
> MODE_SENSE Complete
> Enter tld commands (? returns help information)
> s d
> drive 1 (addr 32) access = 1 Contains Cartridge = Yes
> Barcode = 000001L4
> SCSI ID from drive 1 is 0
> READ_ELEMENT_STATUS Complete
>
> I tried double-checking the barcode result, by doing a robot inventory.
> 000001L4 was not included in the inventory, but I'm almost positive it's
> in there.
>
>
> -----Original Message-----
> From: Justin Piszcz [mailto:jpiszcz AT lucidpixels DOT com]
> Sent: Tuesday, April 13, 2010 10:12 AM
> To: WEAVER, Simon (external)
> Cc: McDonald II, James F.; veritas-bu AT mailman.eng.auburn DOT edu
> Subject: Re: [Veritas-bu] Cannot Write to Tape
>
> Hi,
>
> Reboot the master, run robtest and run "s d" does it show the drives OK?
>
> Justin.
>
> On Tue, 13 Apr 2010, WEAVER, Simon (external) wrote:
>
>> Have you rebooted the Master just in case?
>> Anything changed to cause this problem?
>> Have you enabled any logging?
>>
>> Simon
>>
>> ________________________________
>>
>> From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
>> [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of
> McDonald
>> II, James F.
>> Sent: Tuesday, April 13, 2010 1:43 PM
>> To: veritas-bu AT mailman.eng.auburn DOT edu
>> Subject: [Veritas-bu] Cannot Write to Tape
>>
>>
>>
>> My backups write to disk without any problem, but when I try to run a
>> Tape Backup I get one of three status codes: 200, 252 or 800.  I have
>> researched all three and still have not been able to come up with a
>> solution.  I am running NBU 6.5 for Windows on a Dell 2950 with Server
>> 2003 as the OS.  The tape drive is a Dell PV-124T.  Diagnostics run
> from
>> the tapeloader all seem to pass and the inventories run from within
> NBU
>> all seem to be correct, but I can't get anything to begin to write.
>>
>>
>>
>> Thanks,
>>
>>
>>
>> James McDonald
>>
>> System Administrator
>>
>> SAIC - IISBU
>>
>> 410-312-2232
>>
>> mcdonaldjf AT saic DOT com <mailto:mcdonaldjf AT saic DOT com>
>>
>>
>>
>>
>> This email (including any attachments) may contain confidential
>> and/or privileged information or information otherwise protected
>> from disclosure. If you are not the intended recipient, please
>> notify the sender immediately, do not copy this message or any
>> attachments and do not use it for any purpose or disclose its
>> content to any person, but delete this message and any attachments
>> from your system. Astrium disclaims any and all liability if this
>> email transmission was virus corrupted, altered or falsified.
>> -o-
>> Astrium Limited, Registered in England and Wales No. 2449259
>> Registered Office:
>> Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
>>
>
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>