Install Netbackup and get your library working.

Put your catalog backup tape in the library.

Inventory the catalog backup tape.

Run Phase I and Phase II import of the Catalog Tape

Restore the drfile from the tape (unless you already have it available)

Use the Catalog Recovery Wizard to restore the Catalog (and other bits)

 

-Jonathan

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Spearman, David
Sent: Wednesday, October 21, 2009 1:07 PM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] NBU 6.5.3 master tanked

 

Our Windows 6.5.3 master tanked at the worst possible time. We have a scaler i2000 with 10 lto-4 drives attached. I have read the instructions from veritas on using bprecover a dozen times and cannot for the life of me figure out what they are trying to say.

 

1.       Put tape in drive (fine, which one?)

2.       Run command bprecover –r –ALL –tpath device_path<tape drive>  ?????

The examples are garbage

 

Any help?

 

 