Veritas-bu

Re: [Veritas-bu] Error Code 25

2009-06-23 12:30:48
Subject: Re: [Veritas-bu] Error Code 25
From: "Scott Jacobson" <SJACOBSO AT novell DOT com>
To: "Fogarty, Steve" <steve.fogarty AT gmail DOT com>, Patrick <netbackup AT whelan-consulting.co DOT uk>
Date: Tue, 23 Jun 2009 10:23:35 -0600
Also try:
 
/usr/openv/netbackup/bin/admincmd/bptestbpcd -client <sun_client_fqn> for all test scenarios you've listed below.
 
If this command works for all except for media server #2, you may want to look at bp.conf entries.
 
Do other clients backup properly when assigned for use with media server #2?
 
-sj

>>> Steve Fogarty <steve.fogarty AT gmail DOT com> 6/23/2009 7:24 AM >>>
What do the following commands return?

/usr/openv/netbackup/bin/bpclntcmd -hn <hostname>

/usr/openv/netbackup/bin/bpclntcmd -get_pbx_port <hostname>

Steve




On Tue, Jun 23, 2009 at 9:39 AM, Patrick <netbackup AT whelan-consulting.co DOT uk> wrote:

Has anyone seen the above error in conjunction with:

Client: SunOS client 5.10 Generic_139556-08 i86pc i386 i86pc

Master Server: SuSE10

Media Server SuSE10

Media ServerSuSE10

All running NetBackup 6.5.3.1

telnet <master server> bpcd - works

telnet <first media server> bpcd - times out

telnet <second media server> bpcd - works

Backup of client exits with error code 25 using either media server.

This is driving me up the wall. ANY suggestions would be greatly appreciated .

Regards,

Patrick Whelan

VERITAS Certified NetBackup Support Engineer for UNIX.

VERITAS Certified NetBackup Support Engineer for Windows.

netbackup AT whelan-consulting.co DOT uk

cid:image001.gif@01C99E80.E2717A60


_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>