Hi,
As far as I know you then have to uncheck for multiple streams
on your backup jobs that have this problem. Perhaps make one policy for this.
I have experienced the same problems when backing up a
Enterprise Vault server using multiple streams.
For EV 8 powershell script is used to put EV in backup mode,
only solution I could find was to not use multiple streams.
See also answer from Judy:
2 things.
The parent_end/start
only runs on the master server. So if you use that you will have to
script it to run the command over on the client.
The bpstart/end runs on
the client but – will run for each job on the client. – you can make it
bpstart_notify.policy.schedule .bat so it only runs for jobs in that policy and
that schedule – but again it will run for each child job. So if you use
that, try to make it so it is the only job under that policy.schedule so it
does not run for anything else.
Regards
Kenneth
From: WEAVER, Simon (external)
[mailto:simon.weaver AT astrium.eads DOT net]
Sent: 5. juni 2009 07:40
To: Kenneth Hansen; veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] Pre / Post Scripts on Backup Jobs with
Streams- Revisit with 6.5.3
Hi Kenneth
I used to do this on 5.1 - the problem I found is that for a
client, if it has 3 streams running, the command will STOP the AV, which is great
:-) But if a stream finishes before the other 2 streams have completed, then
the bpend script would restart the AV - That was BEFORE all streams had
completed.
I will relook at these scripts, but are you saying that in 6.5.3
it's behaviour is now different to 5.1?
Cheers
From:
veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Kenneth
Hansen
Sent: Thursday, June 04, 2009 3:56 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Pre / Post Scripts on Backup Jobs with
Streams- Revisit with 6.5.3
Hi,
Use the bpstart_notify and bpend_notify scripts to do this.
On each client make a:
bpstart_notify.bat
bpend_notify.bat
located in C:\Program Files\Veritas\NetBackup\bin catalog
Insert your NET STOP and NET START command in the script files (
bpstart_notify.bat should contain the NET STOP command) on the servers you need
to stop AV.
This should fix your problem J
Regards
Kenneth
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of WEAVER,
Simon (external)
Sent: 4. juni 2009 16:48
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Pre / Post Scripts on Backup Jobs with Streams -
Revisit with 6.5.3
Hello all
I wanted to revisit this problem, seeing as I am on 6.5.3 for
clients and Master / Media / Windows 2003 SP2
Last time I had a problem on Oracle. Good news is, I dont need to
this, but I do have a problem with an Oracle, Exhange and some file level
systems while the AV is running and the Backups runs.
I have a Policy with 10 clients, All Win2k3. This Policy allows for
Multiple Data Streams.
What I need to do is during the backup, I need to shutdown the
Relevant AV services, and restart ONLY when the entire job has completed on the
clients.
I recall a script in 6.5.3 called Parent_start and Parent end. I
just wondered if anyone uses this, or could tell me if this would help me get
around the problem.
Essentially, I only need to use the Windows command NET STOP
<ServiceName> and when the backup completes (regardless of status) NET
START <ServiceName>
With 5.1, it was problematic, as a client could have 5 volumes, and
although I can stop the Service just fine, if one partition ended quickly, the
Service would start up! This is due to the streaming as I read it.
Any advice is very welcome, Thanks again
Simon
This email (including any attachments) may contain confidential and/or privileged information or information otherwise protected from disclosure. If you are not the intended recipient, please notify the sender immediately, do not copy this message or any attachments and do not use it for any purpose or disclose its content to any person, but delete this message and any attachments from your system. Astrium disclaims any and all liability if this email transmission was virus corrupted, altered or falsified. -o- Astrium Limited, Registered in England and Wales No. 2449259 Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England |
No virus
found in this incoming message.
Checked by AVG - www.avg.com
Version: 8.5.339 / Virus Database: 270.12.52/2152 - Release Date: 06/03/09
05:53:00
This email (including any attachments) may contain confidential and/or privileged information or information otherwise protected from disclosure. If you are not the intended recipient, please notify the sender immediately, do not copy this message or any attachments and do not use it for any purpose or disclose its content to any person, but delete this message and any attachments from your system. Astrium disclaims any and all liability if this email transmission was virus corrupted, altered or falsified. -o- Astrium Limited, Registered in England and Wales No. 2449259 Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England |
No virus
found in this incoming message.
Checked by AVG - www.avg.com
Version: 8.5.339 / Virus Database: 270.12.53/2155 - Release Date: 06/04/09
17:55:00