Veritas-bu

Re: [Veritas-bu] Manually eject tapes with vmchange

2009-04-29 12:16:22
Subject: Re: [Veritas-bu] Manually eject tapes with vmchange
From: Travis Kelley <rhatguy AT gmail DOT com>
To: "Baumann, Kevin" <kbaumann AT akamai DOT com>, VERITAS-BU AT mailman.eng.auburn DOT edu
Date: Wed, 29 Apr 2009 12:13:13 -0400
Try:

Vmchange -res -multi_eject -rn $robotnum -rt $robottype -rh $robothost
-ml $tapeid -single_cycle

I'm sure all of these switches aren't necessary but it never hurts to
be specific.

On 4/29/09, Baumann, Kevin <kbaumann AT akamai DOT com> wrote:
> All,
>
>
>
> I am trying to write a script that will eject tapes and I am using the
> following command:
>
>
>
> vmchange -res -multi_eject -rn 0 -rt TLD -rh robot_control_host -ml mediaID
>
>
> This works fine the first time, but the robot no longer works and I need to
> restart Netbackup for the robot to do anything again.  Robtest does not even
> work, it just waits to open the robot device.
>
>
>
> Has anyone seen this before?
>
>
>
> NB Version: 6.5.3
>
> Master server OS: Solaris 10
>
> Robot control server OS: SuSE Linux 10
>
>
>
> The robot is an IBM 3584.
>
>
>
> Thanks.
>
> -Kevin
>
>

-- 
Sent from my mobile device
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu