On Tue, Apr 1, 2008 at 7:45 AM, Clooney, David <david.clooney AT bankofamerica DOT com> wrote:
Thanks Ed
 
Very basically would you suggest the following
 
- build new master to match that of current - 5.1 MP6
- migrate to new master
- upgrade new master to 6.0 MP4

This step isn't needed.
 
- upgrade new master to 6.5.1
- blast old master and make media server

Basically, that's it.  One major change at a time so if something fails, you can back out.   You don't really want to call Symantec and say "I did a migration to new hardware, a new OS release, and upgraded NBU all at the same time and now it doesn't work".

On Solaris 10, watch the tcp_fusion system parameter.  We've found that it has to be disabled on master servers but enabled on media servers.

Log a call before you do your upgrades so they can be ready for you if you do run into problems.

   .../Ed

--