Veritas-bu

Re: [Veritas-bu] sg_install problem with P3000 robot

2007-11-02 22:21:17
Subject: Re: [Veritas-bu] sg_install problem with P3000 robot
From: Blaine Robison <blaine_robison AT yahoo DOT com>
To: g_sperano AT hotmail DOT com, veritas-bu AT mailman.eng.auburn DOT edu
Date: Fri, 2 Nov 2007 19:06:22 -0700 (PDT)
Gary,
The robot will show up as a LUN on the WWN for the bridge.
 
What drivers are you using?  
 It looks like you are using emulex, are you using lpfc to configure it or the SUN drivers?
 
If you are using SUN then you can use cfgadm to configure the devices.
 
If you are using emulex you will have to configure a lpfc.conf file to get persistent bindings. 
 
Blaine Robison
Solaris Ceritfied System Administrator
Solaris Certified Network Administrator
Veritas Certified Professional
972-853-2459
214-578-5391


----- Original Message ----
From: Gary sperano <g_sperano AT hotmail DOT com>
To: veritas-bu AT mailman.eng.auburn DOT edu
Sent: Friday, November 2, 2007 8:37:48 AM
Subject: [Veritas-bu] sg_install problem with P3000 robot

Environment:

            ATL P3000 (robot/drives) connected to a bridge

            Bridge connected to switch-A

            Switch-A connected to NeoScale device

            Neo Scale connected to Switch-B

            Switch-B connets to host HBA

 

NB Hardware

            System Configuration:  Sun Microsystems  sun4u Sun Fire V890

      System clock frequency: 150 MHz

      Memory size: 32768 Megabytes

 

Problem:

      The above NB master server is working fine.  It can connect to the drives and the robot with no issues.  What has changed is that we have built a new master server.  This new master server has the same name as the original master server but a different ip address.  New zones have been set up so that the new master server is zoned to see the P3000 and its tape drives, just like the original master server.  Both masters are online until we can get the new master (sgscan) to see the changer.  Once the new master is situated, we will then migrate from the existing master to the new master. The existing master will be decommissioned and shutdown.

 

      When we run sg_build and sg_install, all is fine.....for the drives, but we continue to receive the following error for the robot

            # /usr/sbin/luxadm -e create_fabric_device -f >>/etc/cfg/fp/fabric_WWN_map

            ID[luxadm.create_fabric_device.2316] configuration failed for line (/devices/pci@9,600000/SUNW,emlxs@2/fp@0,0:fc::210100e08baad429) in file: /etc/cfg/fp/fabric_WWN_map. I/O error

 

      when we run sgscan, sgscan see's the tape devices but does not see the changer (The above message is also produced in the /var/adm/messages log when we initiate sg_install

 

 

Any and all help is appreciated

 

Thanks

Gary

           



__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>