Hi Steven,
This sounds good, if its fine can u please help me embed the same trick.
Is it in the "Selection" script {the RMAN script} or bpstart script, this
clue wd help.
Regards,
BIJU KRISHNAN
On 12/2/06, Steven L. Sesar <ssesar at mitre.org> wrote:
>
> Unfortunately, this is a limitation of NBU's Oracle agent. The exit
> status that you see in the activity monitor is not necessarily the exit
> status of your backup. It is the exit status of the SCRIPT that NBU runs,
> which kicks off your RMAN backup.
>
> What we did to get around this, was to build one monolithic script, which
> parses input passed to it from NBU when any given Oracle policy runs. Based
> on that (and a few other proprietary things), the script shuts down the apps
> associated with the SID that is about to be backed up, shuts down the SID,
> brings it up in startup mount mode, then builds and executes the RMAN code.
>
> The "trick", that we coded in, was that if RMAN fails, the script will
> exit with an artificial exit code, which in turn, gets passed to the
> activity monitor.
>
> Now, anyone that looks at the activity monitor, can trust the exit status
> of any given Oracle backup.
>
> --Steve
>
>
>
> Veritas Netbackup wrote:
>
> Hi All,
>
> I find it strange, say a RMAN backup has 3 streams, 2 of them complete and
> one of them does not appear et all. The backup would still show up as
> complete. The reasons like commn failure e.t.c. are logged in the
> dbclient.
>
> The RMAN catalog displays backup error but the veritas catalog backup is
> success.
>
> I have logged a support request and we are working towards resolving such
> errors. Would be great if the list can help me.
>
> Regards
> BIJU KRISHNAN
>
> ------------------------------
>
> _______________________________________________
> Veritas-bu maillist - Veritas-bu at
> mailman.eng.auburn.eduhttp://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>
>
>
> --
> ===================================
>
> Steven L. Sesar
> Lead Operating Systems Programmer/Analyst
> UNIX Application Services R101
> The MITRE Corporation
> 202 Burlington Road - MS K101
> Bedford, MA 01730
> tel: (781) 271-7702
> fax: (781) 271-2600
> mobile: (617) 519-8933
> email: ssesar at mitre.org
>
> ===================================
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20061202/c7ca9a47/attachment.html
|