Enable logging and look for BPBKAR - or you can create the folder for this
log file, if it does not exist.
HTH
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: <mailto:Simon.Weaver at Astrium-eads.net> Simon.Weaver at
Astrium-eads.net
-----Original Message-----
From: Haskins, Steve [mailto:Steve.Haskins at bannerhealth.com]
Sent: 12 October 2006 16:26
To: WEAVER, Simon; veritas-bu at mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] error 71
Local drive. The client(s) weren't having a problem before the client
version upgrade. Other clients (also updated and existing in the same
policy(s) aren't having an issue. All Local Drives are defined. It doesn't
specify what what file is missing in the file list in the GUI detail, I'm
assuming it may me a temp file that is reoccurringly regenerated by the
application.
Rusty or Simon, What log would I look in?
_____
From: WEAVER, Simon [mailto:simon.weaver at astrium.eads.net]
Sent: Thursday, October 12, 2006 8:16 AM
To: Haskins, Steve; veritas-bu at mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] error 71
Steve
What does it complain about for status 71 - is it system state, drive
letter?
Whats defined in the Policy?
As a test, have you created a TEST Policy, added the client into this policy
and attempted a backup?
Thanks
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: <mailto:Simon.Weaver at Astrium-eads.net> Simon.Weaver at
Astrium-eads.net
-----Original Message-----
From: Haskins, Steve [mailto:Steve.Haskins at bannerhealth.com]
Sent: 12 October 2006 16:01
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] error 71
Hello,
Has anyone experienced an error 71 and been able to resolve it? I am
running Netbackup 5.1MP5 on a Windows system and the client(s) are all
Windows. I opened a case a few years back and the resolution was to update
the client to the same level as the backend but in this case the error
started AFTER updating the client to the same version as the master/media
servers.
Regards and thanks,
Steve
This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender immediately,
do not copy this message or any attachments and do not use it for any
purpose or disclose its content to any person, but delete this message and
any attachments from your system. Astrium disclaims any and all liability if
this email transmission was virus corrupted, altered or falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure. If
you are not the intended recipient, please notify the sender immediately, do
not copy this message or any attachments and do not use it for any purpose or
disclose its content to any person, but delete this message and any attachments
from your system. Astrium disclaims any and all liability if this email
transmission was virus corrupted, altered or falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20061012/a01d1ae6/attachment.html
|