[Veritas-bu] tape drive serial number changed when drive failed - what do I do?

2006-08-09 09:33:21
Subject: [Veritas-bu] tape drive serial number changed when drive failed - what do I do?
From: JMARTI05 at intersil.com (Martin, Jonathan (Contractor))
Date: Wed, 9 Aug 2006 09:33:21 -0400
Windows 2000 5.1 MP4 environment here and it's worked every time.
 
-Jonathan

________________________________

From: jakub.bielecki at comtegra.pl [mailto:jakub.bielecki at comtegra.pl] 
Sent: Wednesday, August 09, 2006 3:17 AM
To: Martin, Jonathan (Contractor)
Cc: Chris.Romano at Lazard.com; veritas-bu at mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] tape drive serial number changed when drive
failed - what do I do?



This procedure didn't work last time I checked (5.1), because browse
button didn't update serial number. 
Usually I delete a drive in GUI and then add a new one with the same
parameters. If it's a shared drive a little more work is needed. 

In 6.0 there is a command utility for replacing a drive, but I can't
remember the name. 

pozdrawiam serdecznie
Jakub Bielecki

-- 
__________________________________________
Jakub.Bielecki at comtegra.pl
Comtegra Sp. z o.o.    http://www.comtegra.pl
ul. Nakielska 3, 01-106 Warsaw, Poland





        "Martin, Jonathan \(Contractor\)" <JMARTI05 at intersil.com> 
Sent by: veritas-bu-bounces at mailman.eng.auburn.edu 

2006-08-08 23:17 

        
        To:        <Chris.Romano at Lazard.com>,
<veritas-bu at mailman.eng.auburn.edu> 
        cc:         
        Subject:        Re: [Veritas-bu] tape drive serial number
changed when drive failed        - what do I do?



I use the GUI in Windows... Goto Devices --> Robot --> Drives.  Select
the drive you replaced and goto properties.  Then "browse" for the new
drive and serial.

Not sure if this works for other OS or SSO etc etc..

-Jonathan 

-----Original Message-----
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of
Chris.Romano at Lazard.com
Sent: Tuesday, August 08, 2006 4:28 PM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] tape drive serial number changed when drive failed
- what do I do?

Hi...

Does anyone know the procedure to follow when a tape drive is
replaced...how do I tell Netbackup about the new serial number?



Thanks,
Chris Romano


_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060809/11bc1b56/attachment.html