Veritas-bu

[Veritas-bu] Dynamic tracking and AIX HBAs

2006-07-08 04:59:27
Subject: [Veritas-bu] Dynamic tracking and AIX HBAs
From: dale at daleking.org (Dale King)
Date: Sat, 8 Jul 2006 18:59:27 +1000
On Fri, Jul 07, 2006 at 11:30:57PM +1000, Jim McD wrote:
> Hi
> A while back somebody wrote this to the list:
> "don't turn on dynamic tracking on the HBA that serves a robot as it is not
> compatible and will cause problems.  Known problem but not well documented."
> 
> Yep I can't find much
> 
> Is the any documentation from Symantec on this in the way of a tech note or 
> the
> like for AIX and dynamic tracking on HBAs?

Hi Jim - this was me.  I'll dig up the veritas ref they sent me when I get
back to work.  Please email me if I forget, or raise a call with them.

I can guarantee you it causes problems - not necessarily right away, but
later on when san fabric changes/events occur.

Regards,
Dale