I'm sorry.  I'm using Netbackup 5.0 MP5 on the server and client

________________________________

From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Hillman,
Eric
Sent: Wednesday, May 17, 2006 2:28 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Windows FS backing up more drives than specified



This is a known bug that was supposed to be fixed pre-MP5 that seems to
still be happening.  We have a Windows policy pointing to a virtual
cluster hostname backing up 5 drives with Allow Multiple Data Streams
turned on.  The first job starts and fails.  The 2nd stream not only
backs up it's assigned drive letter, but continues to backup every other
drive letter specified in the policy even though the other streams are
either queued or are running themselves.  This is a huge pain.  Anyone
know of a fix?

Thanks, 
Eric 


THE INFORMATION CONTAINED IN THIS MESSAGE AND ANY ATTACHMENT MAY BE
PRIVILEGED, CONFIDENTIAL, PROPRIETARY OR OTHERWISE PROTECTED FROM
DISCLOSURE. If the reader of this message is not the intended recipient,
you are hereby notified that any dissemination, distribution, copying or
use of this message and any attachment is strictly prohibited. If you
have received this message in error, please notify us immediately by
replying to the message and permanently delete it from your computer and
destroy any printout thereof.

THE INFORMATION CONTAINED IN THIS MESSAGE AND ANY ATTACHMENT MAY BE PRIVILEGED, 
CONFIDENTIAL, PROPRIETARY OR OTHERWISE PROTECTED FROM DISCLOSURE. If the reader 
of this message is not the intended recipient, you are hereby notified that any 
dissemination, distribution, copying or use of this message and any attachment 
is strictly prohibited. If you have received this message in error, please 
notify us immediately by replying to the message and permanently delete it from 
your computer and destroy any printout thereof.
------_=_NextPart_001_01C679E5.BC346283
Content-Type: text/html; charset=us-ascii
Content-Transfer-Encoding: 7bit

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD><TITLE>Windows FS backing up more drives than specified</TITLE>
<META http-equiv=Content-Type content="text/html; charset=us-ascii">
<META content="MSHTML 6.00.2900.2769" name=GENERATOR></HEAD>
<BODY>
<DIV dir=ltr align=left><FONT face=Arial color=#0000ff size=2><SPAN 
class=490101119-17052006>I'm sorry.&nbsp; I'm using Netbackup 5.0 MP5 on the 
server and client</SPAN></FONT></DIV><BR>
<DIV class=OutlookMessageHeader lang=en-us dir=ltr align=left>
<HR tabIndex=-1>
<FONT face=Tahoma size=2><B>From:</B> veritas-bu-admin AT mailman.eng.auburn 
DOT edu 
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] <B>On Behalf Of 
</B>Hillman, 
Eric<BR><B>Sent:</B> Wednesday, May 17, 2006 2:28 PM<BR><B>To:</B> 
veritas-bu AT mailman.eng.auburn DOT edu<BR><B>Subject:</B> [Veritas-bu] 
Windows FS 
backing up more drives than specified<BR></FONT><BR></DIV>
<DIV></DIV><!-- Converted from text/rtf format -->
<P><FONT face=Arial size=2>This is a known bug that was supposed to be fixed 
pre-MP5 that seems to still be happening.&nbsp; We have a Windows policy 
pointing to a virtual cluster hostname backing up 5 drives with Allow Multiple 
Data Streams turned on.&nbsp; The first job starts and fails.&nbsp; The 2nd 
stream not only backs up it's assigned drive letter, but continues to backup 
every other drive letter specified in the policy even though the other streams 
are either queued or are running themselves.&nbsp; This is a huge pain.&nbsp; 
Anyone know of a fix?</FONT></P>
<P><FONT face=Arial size=2>Thanks,</FONT> <BR><FONT face=Arial 
size=2>Eric</FONT> </P><BR>THE INFORMATION CONTAINED IN THIS MESSAGE AND ANY 
ATTACHMENT MAY BE PRIVILEGED, CONFIDENTIAL, PROPRIETARY OR OTHERWISE PROTECTED 
FROM DISCLOSURE. If the reader of this message is not the intended recipient, 
you are hereby notified that any dissemination, distribution, copying or use of 
this message and any attachment is strictly prohibited. If you have received 
this message in error, please notify us immediately by replying to the message 
and permanently delete it from your computer and destroy any printout 
thereof.</BODY></HTML>
<br>
THE INFORMATION CONTAINED IN THIS MESSAGE AND ANY ATTACHMENT MAY BE PRIVILEGED, 
CONFIDENTIAL, PROPRIETARY OR OTHERWISE PROTECTED FROM DISCLOSURE. If the reader 
of this message is not the intended recipient, you are hereby notified that any 
dissemination, distribution, copying or use of this message and any attachment 
is strictly prohibited. If you have received this message in error, please 
notify us immediately by replying to the message and permanently delete it from 
your computer and destroy any printout thereof.
------_=_NextPart_001_01C679E5.BC346283--

<Prev in Thread] Current Thread [Next in Thread>