Veritas-bu

[Veritas-bu] Renaming NB 6.0MP2 servers

2006-05-11 02:00:15
Subject: [Veritas-bu] Renaming NB 6.0MP2 servers
From: simon.weaver AT astrium.eads DOT net (WEAVER, Simon)
Date: Thu, 11 May 2006 07:00:15 +0100
Steve
Any docs?

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator

EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver AT Astrium-eads DOT net



-----Original Message-----
From: Steven L. Sesar [mailto:ssesar AT mitre DOT org]
Sent: 10 May 2006 15:39
To: WEAVER, Simon
Cc: 'Justin Piszcz'; Karl.Rossing AT federated DOT ca; veritas-bu
Subject: Re: [Veritas-bu] Renaming NB 6.0MP2 servers


I've done it - it was actually a more complex problem in my case: I
cooked 4 master servers (1 Windows, 3 Solaris) down into one Solaris
master. It was a very time-consuming and involved process. It worked
just fine, however there are a ton of "gotchas" along the way. I did a
lot of scripting, both beforehand and on the fly, in order to get this
to work. I also had a very good working knowledge of NBU and its
internals. please be sure that you really need to do this before
attempting it.

--Steve

WEAVER, Simon wrote:

> */It can be done - I just spoke to someone but told me its a drawn out
> process (not supported by Symantec) but it could work./*
> *//*
> */Not too sure how much of a risk it is/*
> 
> 
>
> /Regards/
>
> /Simon Weaver
> *3rd Line Technical Support
> Windows Domain Administrator*/
>
> /EADS Astrium Limited, B32AA IM (DCS)/
> /Anchorage Road, Portsmouth, PO3 5PU/
>
> /Email: //Simon.Weaver AT Astrium-eads DOT net/
> <mailto:Simon.Weaver AT Astrium-eads DOT net>
>
>     -----Original Message-----
>     *From:* Justin Piszcz [mailto:jpiszcz.backup AT gmail DOT com]
>     *Sent:* 10 May 2006 11:49
>     *To:* Karl.Rossing AT federated DOT ca
>     *Cc:* veritas-bu
>     *Subject:* Re: [Veritas-bu] Renaming NB 6.0MP2 servers
>
>     Not supported under 5.1x and when I opened a ticket concerning
>     this they said there is no supported method, only if it is REALLY
>     necessary you can call Veritas' consulting services and have them
>     fix it.
>
>     On 5/9/06, *Karl.Rossing AT federated DOT ca
>     <mailto:Karl.Rossing AT federated DOT ca>* <Karl.Rossing AT federated DOT 
> ca
>     <mailto:Karl.Rossing AT federated DOT ca>> wrote:
>
>
>         I'd like to rename a NB 6.0MP2 master server. In fact, i want
>         to clone my master production server  and rename it at our DR
>         site.
>
>         As far as i know this isn't really supported yet.
>
>           
>         
>                       *Karl-Frédéric Rossing,* 
>         
>         Technical Services 
>         
>
>         
>         
>         
>         
>
>         
>               phone:  204-786-6431 
>         
>         fax:  204-784-6755 
>         
>         toll free:    1-800-665-1934 
>         
>         www.federated.ca <http://www.federated.ca> 
>         
>
>
>         
>         
>
>
>         _CONFIDENTIALITY NOTICE _
>         The information in this email may be confidential and/or
>         legally privileged. This email is intended to be reviewed by
>         only the individual(s) or organization(s) named above. If you
>         are not the intended recipient or an authorized representative
>         of the intended recipient, you are hereby notified that any
>         review, dissemination or copying of this email and its
>         attachments, if any, or the information contained herein is
>         prohibited. If you have received this email in error, please
>         immediately notify the sender by return email and delete this
>         email and its attachments from your system. Thank you.
>
>
> This email is for the intended addressee only.
> If you have received it in error then you must not use, retain,
> disseminate or otherwise deal with it.
> Please notify the sender by return email.
> The views of the author may not necessarily constitute the views of
> EADS Astrium Limited.
> Nothing in this email shall bind EADS Astrium Limited in any contract
> or obligation.
>
> EADS Astrium Limited, Registered in England and Wales No. 2449259
> Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1
> 2AS, England
>



This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate or 
otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS 
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or 
obligation.

EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England


<Prev in Thread] Current Thread [Next in Thread>