[Veritas-bu] Unable to SCSI unload drive
2006-02-28 08:27:33
Subject: |
[Veritas-bu] Unable to SCSI unload drive |
From: |
jlightner AT water DOT com (Jeff Lightner) |
Date: |
Tue, 28 Feb 2006 08:27:33 -0500 |
I've seen this on HP-UX. We have fibre bridges going to the SCSI drives and
usually booting the fibre bridge and power cycling the drive takes care of it.
In fact just power cycling the drive has taken care of it on a couple of
occasions.
-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu [mailto:veritas-bu-admin
AT mailman.eng.auburn DOT edu] On Behalf Of ida3248b AT post.cybercity DOT dk
Sent: Tuesday, February 28, 2006 8:02 AM
To: Paul Esson; veritas-bu AT mailman.eng.auburn DOT edu
Cc: veritas-bu-admin AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Unable to SCSI unload drive
Hello Paul
I have seen this before, in our case it was usually a problem with the drive
or SAN-connection.
I would offline/online the port in the SAN switch and recreate the device
file for this drive. Then use robtest mount/dismount a tape in the drive.
Regards
Michael
On Tue, 28 Feb 2006 12:05:32 -0000, Paul Esson wrote
> Folks,
>
> Has anyone seen this message before? This is from a Red Hat 7.x Media
Server with FC LTO-2 drives attached via Brocade 3800 switches and QLA2340
HBAs.
>
> Feb 23 00:26:04 abzlxre1 tldd[1282]: TLD(0) drive 15 (device 0) is being
DOWNED, status: Unable to SCSI unload drive
> Feb 23 00:26:04 abzlxre1 tldd[1282]: Check integrity of the drive, drive
path, and media
>
> The installation is a v5.1 MP3 set-up with a W2K3 Master Server and a
number of W2K and W2K3 Media Servers. The Linux Media Server has exclusive
use of two LTO drives but is running NBU v4.5. I can't find a decent hit on
the Veritas site or generally and wondered if anyone on the list had been
here before?
>
> Regards,
> Paul Esson
> Redstor Limited
> Direct: +44 (0) 1224 595381
> Mobile: +44 (0) 7766 906514
> E-Mail: paul.esson AT redstor DOT com
> Web: www.redstor.com
> REDSTOR LIMITED
> Torridon House
> 73-75 Regent Quay
> Aberdeen
> UK
> AB11 5AR
> Disclaimer:
> The information included in this e-mail is of a confidential nature and is
intended only for the addressee. If you are not the intended addressee, any
disclosure, copying or distribution by you is prohibited and may be
unlawful. Disclosure to any party other than the addressee, whether
inadvertent or otherwise is not intended to waive privilege or
confidentiality.
>
--
Cybercity Webhosting (http://www.cybercity.dk)
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
|
|