Hello Paul

You can use regedit to make a .reg file you can merge into the registry on 
the new server. I have done this for clients for fast setup.

I havn't tried on a master but I can't see why it shouldn't work.

Regards
Michael

On Wed, 1 Jun 2005 10:45:56 +0100, Paul Esson wrote
> Fabrice,

>

 

> I am expecting to do a bprecover but my point is what is in the Windows 
registry on the existing server that is specific

> to the NetBackup set-up that will not transfer as part of the recover and 
how can I capture it?

>

 

> Regards,

>

 

>
> Paul Esson
> Redstor Limited

> Direct:            +44 (0) 1224 595381
> Mobile:           +44 (0) 7766 906514
> E-Mail:           paul.esson AT redstor DOT com
> Web:               www.redstor.com
> REDSTOR LIMITED
> Torridon House
> 73-75 Regent Quay
> Aberdeen
> UK
> AB11 5AR
> Disclaimer:
> The information included in this e-mail is of a confidential nature and is 
intended only for the addressee.  If you are not the intended addressee, any 
disclosure, copying or distribution by you is prohibited and may be 
unlawful.  Disclosure to any party other than the addressee, whether 
inadvertent or otherwise is not intended to waive privilege or 
confidentiality.

>
> 
-----------------------------------------------------------------------

> From: Brochart, Fabrice [mailto:fabrice_brochart AT storagetek DOT com]
> Sent: 01 June 2005 09:41
> To: Paul Esson; veritas-bu AT mailman.eng.auburn DOT edu
> Subject: RE: [Veritas-bu] Moving Windows Master Server to New Hardware

>

 

> Hi Paul,

>  

> Why don't you reinstall NetBackup on your new server and then do a 
bprecover of the old ?

>  

> Hth

>  

> F@b

>

 

> 
-----------------------------------------------------------------------

> De : veritas-bu-admin AT mailman.eng.auburn DOT edu [mailto:veritas-bu-
admin AT mailman.eng.auburn DOT edu] De la part de Paul Esson
> Envoyé : mercredi 1 juin 2005 09:54
> À : veritas-bu AT mailman.eng.auburn DOT edu
> Objet : [Veritas-bu] Moving Windows Master Server to New Hardware

> Folks,

>

 

> I come from a UNIX background and am faced with moving a Windows 5.1 Master 
Server to new hardware.  The hostname and IP address will remain constant but 
I am concerned about Registry information specific to NetBackup.  Am I 
correct in thinking that what is held in flat files as part of the NetBackup 
application on UNIX is actually kept in the Registry on Windows?  If so how 
have others addressed this?  Extracted the Veritas branch form 
HKEY_LOCAL_MACHINE\SOFTWARE perhaps or am I wide of the mark here?

>

 

> Regards,

>

 

> Paul Esson
> Redstor Limited

> Direct:            +44 (0) 1224 595381
> Mobile:           +44 (0) 7766 906514
> E-Mail:           paul.esson AT redstor DOT com
> Web:               www.redstor.com
> REDSTOR LIMITED
> Torridon House
> 73-75 Regent Quay
> Aberdeen
> UK
> AB11 5AR
> Disclaimer:
> The information included in this e-mail is of a confidential nature and is 
intended only for the addressee.  If you are not the intended addressee, any 
disclosure, copying or distribution by you is prohibited and may be 
unlawful.  Disclosure to any party other than the addressee, whether 
inadvertent or otherwise is not intended to waive privilege or 
confidentiality.

>

 

--
Cybercity Webhosting (http://www.cybercity.dk)


<Prev in Thread] Current Thread [Next in Thread>