I missed the 'No Connect Back' option on the master server client attributes
portion.
That did the trick. Thanks Guys!
-Daniel
On 11/9/04 4:56 PM, "Wayne T Smith" <wts AT maine DOT edu> wrote:
> Hi Daniel,
>
> I think you'll find that you haven't opened enough. Even with vnetd,
> the master/media server(s) must be able to initiate a conversation.
>
> I open these 4 ports ... in both directions: 13720, 13724, 13782, 13783.
>
> cheers, wayne
>
> Daniel Teklu wrote, in part, on 11/9/2004 3:55 PM:
>
>> I am using Netbackup 5.0 on solaris 9 master and client.
>>
>> I am trying to backup a client behind a firewall. We opened bpcd port
>> (13782) from master to client and vnetd port (13724) from client to
master.
>>
>> And I manually run the ./bpclient -client client_name -add
-connect_nr_port
>> 1
>>
>> I am still having a problem connecting from one to the other.
>>
>> Any idea how to do this or a tech not available?
>>
>> Thanks
>> -Daniel
>> _______________________________________________
>> Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
>> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>>
>>
|