Veritas-bu

[Veritas-bu] Catalog recovery to a different Master ?

2004-03-31 08:05:15
Subject: [Veritas-bu] Catalog recovery to a different Master ?
From: ebarlow AT usatoday DOT com (Barlow, Eliott)
Date: Wed, 31 Mar 2004 08:05:15 -0500
What if you modified the host's host file to evade the reverse lookup? 

Eli

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Paul
Gimpelev
Sent: Wednesday, March 31, 2004 7:51 AM
To: Arun K Sadaram; veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Catalog recovery to a different Master ?

        Probably not.  To be able to use the catalog from "Master A" you
will
need to at least fool the host that is "Master B" into thinking it has
the same
name as "Master A".  You will still not be able to run the restores from
the
imposter master because clients will do a reverse lookup on the IP and
it will
not match the name of "Master A".

paulg

On Mar 31,  7:58am, Arun K Sadaram wrote:
> Subject: [Veritas-bu] Catalog recovery to a different Master ?
>
> Hi,
>
>
> A quick question: I have a Solaris Master NetBackup DC4.5 being
cataloged
daily. We want to verify the catalog recovery and run few test restores
using a
different (secondary) NetBackup Master server @ some frequency. Please
let me
know whether or not i can recover the NetBackup catalog from one Master
server
to a different Master server (with a different name and I.P.address) and
run
the restoration to the same NB clients that are backedup using primary
Master?
>
>
>
> Any help would be greatly appreciated?
>
>
> Kind Regards
> -Arun
>
>
> Have a great day!!
> Win an evening with the Indian cricket captain: Yahoo! India Promos.
>
> [ Attachment (text/x-html): ".prt25766Z-fbb" 1487 bytes
>   Character set: iso-8859-1 ]
>-- End of excerpt from Arun K Sadaram


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu