[Veritas-bu] RE: problem adding new drive to our L180
2003-07-07 15:08:01
Subject: |
[Veritas-bu] RE: problem adding new drive to our L180 |
From: |
cheryl.king AT intrado DOT com (King, Cheryl) |
Date: |
Mon, 7 Jul 2003 13:08:01 -0600 |
It turned out to be a problem in the router in the L180 robot. The engineer
telneted to the router and did option 1 (perform Configuration)>5 (Fibre
Channel to SCSI Mapping Configuration)>5 (Show/Edit Fibre Channel to SCSI
Mapping Mode)>F to fill. Then reboot the router and then did the following
procedure from a response I received (sorry I deleted the Email and don't
remember who sent it).
setenv auto-boot? false
reset-all
probe-scsi-all
look for the new tape drive
...when done...
setenv auto-boot? true
boot
Thank you so much for the help.
> -----Original Message-----
> From: King, Cheryl
> Sent: Wednesday, July 02, 2003 2:57 PM
> To: Veritas-Bu (E-mail)
> Subject: problem adding new drive to our L180
>
> STK installed a new drive (the third) to our L180 connected to a SUN running
> NetBackup 4.5. I did the following but the Sun doesn't see the new drive.
>
> touch /reconfigure
> shutdown the SUN server and L180
> installed the drive and verified that the robot had three drives
> brought up the SUN server
>
> Any ideas would be appreciated.
>
> Cheryl King
> Systems Administrator II
> Intrado Inc.
> 1601 Dry Creek Road
> Longmont, CO 80503-6493
> direct: 720.864.5162
> fax: 720.494.6600
> email: cheryl.king AT intrado DOT com
>
> Intrado. Informed Response.TM
> <www.intrado.com>
>
> The information contained in this electronic message and any attachments to
> this message are intended for the exclusive use of the addressee(s) and may
> contain confidential or privileged information. If you are not the intended
> recipient, please notify Intrado Inc. immediately at (720) 494-5800 and
> destroy all copies of this message and any attachments.
>
>
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- [Veritas-bu] RE: problem adding new drive to our L180,
King, Cheryl <=
|
|
|