Veritas-bu

[Veritas-bu] move tapes from CAP to slots ??

2003-06-05 13:57:36
Subject: [Veritas-bu] move tapes from CAP to slots ??
From: rajeevprasad AT att DOT com (Prasad, Rajeev, NPONS)
Date: Thu, 5 Jun 2003 13:57:36 -0400
Thanks a lot !!

-----Original Message-----
From: Donaldson, Mark [mailto:Mark.Donaldson AT experianems DOT com]
Sent: Thursday, June 05, 2003 12:52 PM
To: Prasad, Rajeev, NPONS; Donaldson, Mark; Brochart, Fabrice; David A.
Chapa; veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] move tapes from CAP to slots ??


the -empty_ie is the vmudate option to remove tapes from the CAP & place
them in slots automatically.  The library or NB determines in which slots
they're placed (I'm not sure which).  When complete, NB will update its
inventory of tapes (volume database) to add the new tapes to the library
inventory.

"empty_ie" is short for "empty the import/export slots".

HTH - Mark

-----Original Message-----
From: Prasad, Rajeev, NPONS [mailto:rajeevprasad AT att DOT com]
Sent: Thursday, June 05, 2003 11:41 AM
To: Donaldson, Mark; Brochart, Fabrice; David A. Chapa;
veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] move tapes from CAP to slots ??


sorry, but wat does empty_ie does? formats data out of tape? will this
command give the tapes a slot no. to which i can move them?

thnaks,
-rajeev

-----Original Message-----
From: Donaldson, Mark [mailto:Mark.Donaldson AT experianems DOT com]
Sent: Thursday, June 05, 2003 11:32 AM
To: Prasad, Rajeev, NPONS; Brochart, Fabrice; David A. Chapa;
veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] move tapes from CAP to slots ??


You can do this with the vmupdate command:

v3.4
vmupdate -rn <robnum> -rt <robtype> -rh <robhost> \
    -empty_ie -use_barcode_rules \
    -involgrp <in_vgname> -outvolgrp <out_vgname>

v4.5
vmupdate -rn <robnum> -rt <robtype> -rh <robhost> \
    -empty_map -use_barcode_rules \
    -involgrp <in_vgname> -outvolgrp <out_vgname>

-----Original Message-----
From: Prasad, Rajeev, NPONS [mailto:rajeevprasad AT att DOT com]
Sent: Thursday, June 05, 2003 10:19 AM
To: Brochart, Fabrice; David A. Chapa; veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] move tapes from CAP to slots ??


Hi all,

what do i need to do to move tapes from CAP to slots? (except m i<n> s<n>)
coz, the vmquery -m <ev> does not show the slot no. on the tape details.
Also, robot type is: "NONE - Not Robotic (0)" 

it is stk lib & tapes r in CAP.

plz. help.
thanks,
Rajeev

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu