Hi Guys,
To backup Duncan's diagnosis of a socket level problem -
I have seen this when the client or server was clustered or a cluster member
in some way and using virtual Interfaces.
I have seen when using both SUN Cluster 3 and SAFEKIT,
You can see the connectivity issues detailed below........note dnnm1003
(x.x.x.175) is the hostname of the virtual interface for the cluster,
dnnm1002 is the actual interface of the cluster member housing the netbackup
app
Server netstat - dnnm1002 ( FAILS )
dnnm1003.om.digifone.com.860 laurence-solaris.om.digifone.com.bpcd 24820
0
8760 0 CLOSE_WAIT
server netstat - dmmn1002 ( SUCCEEDS )
dnnm1002.om.digifone.com.bpcd dnnm1002.om.digifone.com.989 32768 0
32768
0 ESTABLISHED
client netstat - dmmn1002 - ( FAILS )
# netstat -a | grep bp
*.bpcd *.* 0 0 24576 0 LISTEN
*.bpjava-msvc *.* 0 0 24576 0 LISTEN
laurence-solaris.bpcd x.x.x.175.981 8760 0 24820 0 FIN_WAIT_2
client netstat dmmn1002 - ( SUCCEEDS )
# netstat -a | grep bp
*.bpcd *.* 0 0 24576 0 LISTEN
*.bpjava-msvc *.* 0 0 24576 0 LISTEN
laurence-solaris.bpcd dnnm1002.745
I had to resolve by adding the actual ip's of the cluster nodes, plus the
virtual ip of the cluster, ALL as servers in the bp.conf of both the master
and the client machines.
Regards
Laurence
****************************************************************************************
This E-mail is from O2. The E-mail and any files
transmitted with it are confidential and may also be privileged and intended
solely for the use of the individual or entity to whom they are addressed.
Any unauthorised direct or indirect dissemination, distribution or copying
of this message and any attachments is strictly prohibited. If you have
received the E-mail in error please notify postmaster AT O2 DOT com or
telephone ++ 353 1 6095000.
*****************************************************************************************
|
|
|