Mark 

One of the things I found to be *very* useful in identifying the actual media 
servers is using bpstulist, since only storage units are created for "real" 
media servers.  

When I was re-writing many of my scripts that was the biggest hurdle...couldn't 
rely on the bp.conf SERVER= entry because many of my clients had administrative 
clients set up, thus requiring a SERVER = entry.  So bpstulist ended up being 
the best cli I found to identify the media servers in the Master's domain.


David


Quoting "Donaldson, Mark" <Mark.Donaldson AT experianems DOT com>:

> I'm converting a lot of my scripts from my current environment, a single
> master/media server, to a new environment with one master/media & three
> more
> SSO media servers.  
> 
> Anybody have advice?  Any commands that'll have to be specially
> paid-attention-to where multiple media servers will bite my butt?  Right
> now
> I'm scanning man pages for options where media server an option (like
> vmoprcmd) and using that as my cue that alterations are necessary.
> 
> -M
> 