[Veritas-bu] Backups failing with error code 219

2002-09-04 10:27:22
Subject: [Veritas-bu] Backups failing with error code 219
From: david AT datastaff DOT com (David A. Chapa)
Date: Wed, 4 Sep 2002 09:27:22 -0500
Verify that the density is correct for your media in your media manager and
the storage unit on your master.


I have noticed with the Windows version that occasionally when you use the
Wizard to create a STU, it will use DLT2 or one of the other alternate media
types.  Perhaps someone recreated the STU?

In any case, I'd check that out.

David

<><><><><><><><><><><><><><><><><><><><>
David A. Chapa
Backup Storage Consultant
DataStaff, Inc.
http://www.datastaff.com
312 683 1144
---------------------------------------

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of WEAVER,
Simon
Sent: Wednesday, September 04, 2002 8:59 AM
To: 'David Brown'
Cc: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: RE: [Veritas-bu] Backups failing with error code 219


Dave
In the backup policy jobs, have you tried choosing the Master Server?
Also in the Schedule you get an option to override the storage unit!

Let me know!

Simon Weaver
NT Domain Administrator
Ext. 5544
Tel: 02392-705544 (Direct Dial)
Simon.Weaver AT Astrium-Space DOT com

-----Original Message-----
From: David Brown [mailto:browndav AT bronsonhg DOT org]
Sent: 04 September 2002 01:10:PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Backups failing with error code 219

Hopefully someone can provide some assistance to this new problem for me:

We are running Netbackup 4.5 on a Win2000 machine.  We are using one master
and one media server, both at 4.5.  Last night, all backups running through
the master server would instantly fail with the '219' error code, storage
unit unavailable.

We pointed all backups to run through the media server instead of the master
and everything ran fine.  Both machines are identical in their operating
systems and they are both set to only see the one 9714 tape library.
Everything had been running fine for the past few month, this problem just
appeared last night.

Any ideas what would cause this 219 error on the master all of a sudden?  We
have tried shutting down and restarting the master server a couple of times
but it has not cleared up the problem.

Thanks!

David Brown
McKesson Information Solutions
Bronson Methodist Hospital
browndav AT bronsonhg DOT org
(269) 341-7054 : office
(269) 217-0743 : cell
(269) 212-0273 : pager

Confidentiality Notice: This e-mail message, including any attachments, is
for the sole use of the intended recipient(s) and may contain confidential
and privileged information.  Any unauthorized review, use, disclosure or
distribution is prohibited.  If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all copies of the original
message.


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
...
This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate
or otherwise deal with it.  Please notify the sender by return email.
The views of the author may not necessarily constitute the views of Astrium
Limited.
Nothing in this email shall bind Astrium Limited in any contract or
obligation.

Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


<Prev in Thread] Current Thread [Next in Thread>