Go into Media manager, and select all the tapes, and move them out of the
robot, in the GUI. Leave them in the robot physically.
Then exit everything, bp.kill_all and then bpps -a make sure everything is
dead, S77netbackup, and then reinventory the robot.
Bob
----- Original Message -----
From: "Dennis Dwyer" <dfdwyer AT tecoenergy DOT com>
To: <Veritas-bu AT mailman.eng.auburn DOT edu>
Sent: Thursday, August 09, 2001 3:04 PM
Subject: [Veritas-bu] TLD Robot Errors During Inventory of L700
> I've noticed that I get several "Volume Database and TLD(x) Conflict"
errors whenever I try to inventory and synch my new L700 and my NBU volume
database. Here's the message:
>
> ERROR - Volume Database and TLD(1) Conflict:
> database: Slot 39 is not found
> TLD(1) Slot 39 contains barcode 000086
>
> I get this message for (18) slots. I'm looking for guidance on how to
remedy this. I'm thinking I might be able to manually pull the tapes out of
these slots with errors, reconcile the inventory and then manually add each
tape back into the library through the CAP or using the bpinject script from
bpvault.
>
> What say you all?
>
> Regards,
> Dennis
>
> Quote: "Time is not a test of the truth"
> Translation: Just because you've always done it that way, doesn't make it
right
>
> Dennis F. Dwyer
> Enterprise Storage Manager
> Tampa Electric Company
>
> (813) 225-5181 - Voice
> (813) 275-3599 - FAX
>
> Visit our corporate website at www.tecoenergy.com
>
> _______________________________________________
> Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>
|