[Veritas-bu] Re: Windows 2000 clustering

2001-07-11 15:31:28
Subject: [Veritas-bu] Re: Windows 2000 clustering
From: tgreen AT mitra DOT com (Terry Green)
Date: Wed, 11 Jul 2001 15:31:28 -0400
We've been working with an Exchange cluster, and it seems OK with using
the virtual server name as a client.

We've done both backups and restores of the Exchange data using the
virtual name, and moved the service around on the cluster... seems
pretty good.

-----Original Message-----
From: veritas-bu-request AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-request AT mailman.eng.auburn DOT edu]
Sent: Wednesday, July 11, 2001 2:48 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Veritas-bu digest, Vol 1 #549 - 12 msgs


Send Veritas-bu mailing list submissions to
        veritas-bu AT mailman.eng.auburn DOT edu

To subscribe or unsubscribe via the World Wide Web, visit
        http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
or, via email, send a message with subject or body 'help' to
        veritas-bu-request AT mailman.eng.auburn DOT edu

You can reach the person managing the list at
        veritas-bu-admin AT mailman.eng.auburn DOT edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Veritas-bu digest..."


Today's Topics:

   1. format of bpstulist (Jason Ahrens)
   2. Re: format of bpstulist (scott.kendall AT abbott DOT com)
   3. RE: format of bpstulist (Jason Ahrens)
   4. RE: format of bpstulist (Tim McMurphy)
   5. RE: format of bpstulist (Jason Ahrens)
   6. Client Oracle Hotbackup failures (Daniel Chrastil)
   7. RE: format of bpstulist (Jason Ahrens)
   8. Re: Client Oracle Hotbackup failures (Diane M. Meeker)
   9. NBU 3.4 auth.conf file (Tricia A Novak)
  10. Windows 2000 Clustering (Brian_Drager AT Vanguard DOT com)
  11. Re: NBU 3.4 auth.conf file (Diane M. Meeker)
  12. RE: Windows 2000 Clustering (O'Shea, Don)

--__--__--

Message: 1
From: Jason Ahrens <AhrensJ AT psi DOT ca>
To: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Wed, 11 Jul 2001 13:04:46 -0400
Subject: [Veritas-bu] format of bpstulist

I think I found what I need. I just need to know the value for the
fields
from the bpstulist command. An example of this command came out:

root@veritasmaster1:/usr/openv/netbackup/bin/admincmd# bpstulist -label
STKLIB1
STKLIB1 2 veritasmedia1 8 0 6 4 0 *NULL* 0 1 0 *NULL*

I know one of those 0's is the robot num.. One of the other values is
the
robot type.. Anyone know how to convert?

Thanks

Jason

--
Jason Ahrens
Systems Administrator/Backup Specialist
PSINet Limited
http://www.psi.ca
The Internet SuperCarrier


--__--__--

Message: 2
From: scott.kendall AT abbott DOT com
Subject: Re: [Veritas-bu] format of bpstulist
To: Jason Ahrens <AhrensJ AT psi DOT ca>
Cc: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Wed, 11 Jul 2001 12:18:23 -0500


it's in the manual...

label
stu type
host
robot type
robot number
density
concurrent jobs
initial mpx
path
on demand only
max mpx
maxfrag size
ndmp attach host



 

                    Jason Ahrens <AhrensJ AT psi DOT ca>

                    Sent by:                             To:     Veritas
BU <veritas-bu AT mailman.eng.auburn DOT edu>                    
                    veritas-bu-admin AT mailman DOT eng.        cc:

                    auburn.edu                           Subject:
[Veritas-bu] format of bpstulist                             
 

 

                    07/11/2001 12:04 PM

 

 





I think I found what I need. I just need to know the value for the
fields
from the bpstulist command. An example of this command came out:

root@veritasmaster1:/usr/openv/netbackup/bin/admincmd# bpstulist -label
STKLIB1
STKLIB1 2 veritasmedia1 8 0 6 4 0 *NULL* 0 1 0 *NULL*

I know one of those 0's is the robot num.. One of the other values is
the
robot type.. Anyone know how to convert?

Thanks

Jason

--
Jason Ahrens
Systems Administrator/Backup Specialist
PSINet Limited
http://www.psi.ca
The Internet SuperCarrier

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu





--__--__--

Message: 3
From: Jason Ahrens <AhrensJ AT psi DOT ca>
To: "'scott.kendall AT abbott DOT com'" <scott.kendall AT abbott DOT com>
Cc: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Subject: RE: [Veritas-bu] format of bpstulist
Date: Wed, 11 Jul 2001 13:21:25 -0400

I have to ask...

*which* manual.. I've got about 10 here :P

> -----Original Message-----
> From: scott.kendall AT abbott DOT com [mailto:scott.kendall AT abbott DOT com]
> Sent: July 11, 2001 13:18
> To: Jason Ahrens
> Cc: Veritas BU
> Subject: Re: [Veritas-bu] format of bpstulist
> 
> 
> 
> it's in the manual...
> 
> label
> stu type
> host
> robot type
> robot number
> density
> concurrent jobs
> initial mpx
> path
> on demand only
> max mpx
> maxfrag size
> ndmp attach host

--__--__--

Message: 4
From: Tim McMurphy <Tim.McMurphy AT telus DOT com>
To: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Subject: RE: [Veritas-bu] format of bpstulist
Date: Wed, 11 Jul 2001 11:29:22 -0600

Hey consider that minor. We could tell you to go use Veritas' web site
search engine :)


-----Original Message-----
From: Jason Ahrens [mailto:AhrensJ AT psi DOT ca]
Sent: Wednesday, July 11, 2001 11:21 AM
To: 'scott.kendall AT abbott DOT com'
Cc: Veritas BU
Subject: RE: [Veritas-bu] format of bpstulist


I have to ask...

*which* manual.. I've got about 10 here :P

> -----Original Message-----
> From: scott.kendall AT abbott DOT com [mailto:scott.kendall AT abbott DOT com]
> Sent: July 11, 2001 13:18
> To: Jason Ahrens
> Cc: Veritas BU
> Subject: Re: [Veritas-bu] format of bpstulist
> 
> 
> 
> it's in the manual...
> 
> label
> stu type
> host
> robot type
> robot number
> density
> concurrent jobs
> initial mpx
> path
> on demand only
> max mpx
> maxfrag size
> ndmp attach host
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

--__--__--

Message: 5
From: Jason Ahrens <AhrensJ AT psi DOT ca>
To: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Subject: RE: [Veritas-bu] format of bpstulist
Date: Wed, 11 Jul 2001 13:33:42 -0400

Ok.. I found something in the SysAdmin guide.. However, it's out of
date...
A number of the options it lists are comming back as 'invalid' when I
actually try them (-l, -L, and iU) and it doesn't give the translated
values
of these numbers.

I'll keep plugging.

Jason

> -----Original Message-----
> From: Tim McMurphy [mailto:Tim.McMurphy AT telus DOT com]
> Sent: July 11, 2001 13:29
> To: Veritas BU
> Subject: RE: [Veritas-bu] format of bpstulist
> 
> 
> Hey consider that minor. We could tell you to go use Veritas' web site
> search engine :)

--__--__--

Message: 6
Date: Wed, 11 Jul 2001 13:34:27 -0400
From: "Daniel Chrastil" <dchrastil AT bcbsga DOT com>
Organization: IT-IT-TECHNICAL SUPPORT
To: "veritas-bu AT mailman.eng.auburn DOT edu"
<veritas-bu AT mailman.eng.auburn DOT edu>
Subject: [Veritas-bu] Client Oracle Hotbackup failures

I have a problem with a client with Oracle database extension
installed.  The backup fails with a code 25.  All other hotbackups run
just fine, however they are also running from media servers which have
multi-hosted drives connected.  This backup is being run from a client
which goes over the network to the SAN through a media manager.  Running
DataCenter 3.4 which also requires license keys which have been added on
the media servers.  But where does one enter a license key on a client
for a database extension as there is no goodies or admincmd directory
when you install clients, or does this even matter?  I am sure that the
problem is something simple which I am overlooking here, just been
looking at it so long that I probably need a fresh look from elsewhere.
The oracle output log is below.  The Datacenter all logs entries report
reports a error code of 59 (cannot connect to socket)

Thanks,
Dan Chrastil
BlueCross BlueShield of Georgia


Target database:  pegq
Type of backup:  FULL
Recovery catalog:  r806
Number of channels:  2
Home file system currently at: 56%
Executing RMAN backup...
Archive Disk Space before RMAN BACKUP: 91%

RMAN SCRIPT
---- ------
run {
allocate channel ch1 type 'SBT_TAPE';
allocate channel ch2 type 'SBT_TAPE';
sql 'alter system switch logfile';
backup filesperset 10 format 'df_%u_%s_%p'
(database include current controlfile);
backup filesperset 10 format 'lf_%u_%s_%p'
(archivelog all delete input); }

Archive Disk Space after RMAN BACKUP: 91%
Backup returned errors
Start time:  Tue Jul 10 15:49:10 EDT 2001
End time:    Tue Jul 10 15:49:56 EDT 2001

Recovery Manager: Release 8.0.6.0.0 - Production

RMAN-06005: connected to target database: PEGQ
RMAN-06008: connected to recovery catalog database

RMAN> run {
2> allocate channel ch1 type 'SBT_TAPE';
3> allocate channel ch2 type 'SBT_TAPE';
4> sql 'alter system switch logfile';
5> backup filesperset 10 format 'df_%u_%s_%p'
6> (database include current controlfile);
7> backup filesperset 10 format 'lf_%u_%s_%p'
8> (archivelog all delete input); }
9>
RMAN-03022: compiling command: allocate
RMAN-03023: executing command: allocate
RMAN-08030: allocated channel: ch1
RMAN-08500: channel ch1: sid=11 devtype=SBT_TAPE

RMAN-03022: compiling command: allocate
RMAN-03023: executing command: allocate
RMAN-08030: allocated channel: ch2
RMAN-08500: channel ch2: sid=12 devtype=SBT_TAPE

RMAN-03022: compiling command: sql
RMAN-06162: sql statement: alter system switch logfile
RMAN-03023: executing command: sql

RMAN-03022: compiling command: backup
RMAN-03025: performing implicit partial resync of recovery catalog
RMAN-03023: executing command: partial resync
RMAN-08003: starting partial resync of recovery catalog
RMAN-08005: partial resync complete
RMAN-03023: executing command: backup
RMAN-08008: channel ch1: starting datafile backupset
RMAN-08502: set_count=1 set_stamp=434735357
RMAN-08010: channel ch1: including datafile 6 in backupset
RMAN-08010: channel ch1: including datafile 8 in backupset
RMAN-08010: channel ch1: including datafile 10 in backupset
RMAN-08010: channel ch1: including datafile 3 in backupset
RMAN-08010: channel ch1: including datafile 1 in backupset
RMAN-08008: channel ch2: starting datafile backupset
RMAN-08502: set_count=2 set_stamp=434735357
RMAN-08010: channel ch2: including datafile 5 in backupset
RMAN-08010: channel ch2: including datafile 7 in backupset
RMAN-08010: channel ch2: including datafile 9 in backupset
RMAN-08010: channel ch2: including datafile 2 in backupset
RMAN-08010: channel ch2: including datafile 4 in backupset
RMAN-08011: channel ch1: including current controlfile in backupset
RMAN-00569: ================error message stack follows================
RMAN-03007: retryable error occurred during execution of command: backup

RMAN-07004: unhandled exception during command execution on channel ch1
RMAN-10035: exception raised in RPC: ORA-19624: operation failed, retry
possible
ORA-19506: failed to create sequential file, name="df_01cuj27t_1_1",
parms=""
ORA-27007: failed to open file
HP-UX Error: 1: Not owner
Additional information: 7009
Additional information: 1
ORA-06512: at "SYS.DBMS_BACKUP_RESTORE", line 408
RMAN-10031: ORA-19624 occurred during call to
DBMS_BACKUP_RESTORE.BACKUPPIECECREATE

Recovery Manager complete.


--__--__--

Message: 7
From: Jason Ahrens <AhrensJ AT psi DOT ca>
To: Veritas BU <veritas-bu AT mailman.eng.auburn DOT edu>
Subject: RE: [Veritas-bu] format of bpstulist
Date: Wed, 11 Jul 2001 13:36:58 -0400

Dumb me.. Those work with other options as well.. The error was just
comming
back as unrecognized option, not a more correct 'more options required'
or
something...

> -----Original Message-----
> From: Jason Ahrens [mailto:AhrensJ AT psi DOT ca]
> Sent: July 11, 2001 13:34
> To: Veritas BU
> Subject: RE: [Veritas-bu] format of bpstulist
> 
> 
> Ok.. I found something in the SysAdmin guide.. However, it's 
> out of date...
> A number of the options it lists are comming back as 'invalid' when I
> actually try them (-l, -L, and iU) and it doesn't give the 
> translated values
> of these numbers.
> 
> I'll keep plugging.
> 
> Jason

--__--__--

Message: 8
From: "Diane M. Meeker" <ladydi AT virginia DOT edu>
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Client Oracle Hotbackup failures
Date: Wed, 11 Jul 2001 02:07:08 -0400 (Eastern Daylight Time)


Hello,

You will have to chmod 777 /usr/openv/netbackup/logs/user_ops after your
local client install.

The cp_to_client script from the UNIX Client CD changes the
/usr/openv/netbackup/logs/user_ops 
permissions to 755 which effects Oracle extension client and backups.

Diane

> Date: Wed, 11 Jul 2001 13:34:27 -0400
> From: Daniel Chrastil <dchrastil AT bcbsga DOT com>
> To: "veritas-bu AT mailman.eng.auburn DOT edu"
<veritas-bu AT mailman.eng.auburn DOT edu>
> Subject: [Veritas-bu] Client Oracle Hotbackup failures
> 
> I have a problem with a client with Oracle database extension
> installed.  The backup fails with a code 25.  All other hotbackups run
> just fine, however they are also running from media servers which have
> multi-hosted drives connected.  This backup is being run from a client
> which goes over the network to the SAN through a media manager.
Running
> DataCenter 3.4 which also requires license keys which have been added
on
> the media servers.  But where does one enter a license key on a client
> for a database extension as there is no goodies or admincmd directory
> when you install clients, or does this even matter?  I am sure that
the
> problem is something simple which I am overlooking here, just been
> looking at it so long that I probably need a fresh look from
elsewhere.
> The oracle output log is below.  The Datacenter all logs entries
report
> reports a error code of 59 (cannot connect to socket)
> 
> Thanks,
> Dan Chrastil
> BlueCross BlueShield of Georgia
> 
> 
> Target database:  pegq
> Type of backup:  FULL
> Recovery catalog:  r806
> Number of channels:  2
> Home file system currently at: 56%
> Executing RMAN backup...
> Archive Disk Space before RMAN BACKUP: 91%
> 
> RMAN SCRIPT
> ---- ------
> run {
> allocate channel ch1 type 'SBT_TAPE';
> allocate channel ch2 type 'SBT_TAPE';
> sql 'alter system switch logfile';
> backup filesperset 10 format 'df_%u_%s_%p'
> (database include current controlfile);
> backup filesperset 10 format 'lf_%u_%s_%p'
> (archivelog all delete input); }
> 
> Archive Disk Space after RMAN BACKUP: 91%
> Backup returned errors
> Start time:  Tue Jul 10 15:49:10 EDT 2001
> End time:    Tue Jul 10 15:49:56 EDT 2001
> 
> Recovery Manager: Release 8.0.6.0.0 - Production
> 
> RMAN-06005: connected to target database: PEGQ
> RMAN-06008: connected to recovery catalog database
> 
> RMAN> run {
> 2> allocate channel ch1 type 'SBT_TAPE';
> 3> allocate channel ch2 type 'SBT_TAPE';
> 4> sql 'alter system switch logfile';
> 5> backup filesperset 10 format 'df_%u_%s_%p'
> 6> (database include current controlfile);
> 7> backup filesperset 10 format 'lf_%u_%s_%p'
> 8> (archivelog all delete input); }
> 9>
> RMAN-03022: compiling command: allocate
> RMAN-03023: executing command: allocate
> RMAN-08030: allocated channel: ch1
> RMAN-08500: channel ch1: sid=11 devtype=SBT_TAPE
> 
> RMAN-03022: compiling command: allocate
> RMAN-03023: executing command: allocate
> RMAN-08030: allocated channel: ch2
> RMAN-08500: channel ch2: sid=12 devtype=SBT_TAPE
> 
> RMAN-03022: compiling command: sql
> RMAN-06162: sql statement: alter system switch logfile
> RMAN-03023: executing command: sql
> 
> RMAN-03022: compiling command: backup
> RMAN-03025: performing implicit partial resync of recovery catalog
> RMAN-03023: executing command: partial resync
> RMAN-08003: starting partial resync of recovery catalog
> RMAN-08005: partial resync complete
> RMAN-03023: executing command: backup
> RMAN-08008: channel ch1: starting datafile backupset
> RMAN-08502: set_count=1 set_stamp=434735357
> RMAN-08010: channel ch1: including datafile 6 in backupset
> RMAN-08010: channel ch1: including datafile 8 in backupset
> RMAN-08010: channel ch1: including datafile 10 in backupset
> RMAN-08010: channel ch1: including datafile 3 in backupset
> RMAN-08010: channel ch1: including datafile 1 in backupset
> RMAN-08008: channel ch2: starting datafile backupset
> RMAN-08502: set_count=2 set_stamp=434735357
> RMAN-08010: channel ch2: including datafile 5 in backupset
> RMAN-08010: channel ch2: including datafile 7 in backupset
> RMAN-08010: channel ch2: including datafile 9 in backupset
> RMAN-08010: channel ch2: including datafile 2 in backupset
> RMAN-08010: channel ch2: including datafile 4 in backupset
> RMAN-08011: channel ch1: including current controlfile in backupset
> RMAN-00569: ================error message stack
follows================
> RMAN-03007: retryable error occurred during execution of command:
backup
> 
> RMAN-07004: unhandled exception during command execution on channel
ch1
> RMAN-10035: exception raised in RPC: ORA-19624: operation failed,
retry
> possible
> ORA-19506: failed to create sequential file, name="df_01cuj27t_1_1",
> parms=""
> ORA-27007: failed to open file
> HP-UX Error: 1: Not owner
> Additional information: 7009
> Additional information: 1
> ORA-06512: at "SYS.DBMS_BACKUP_RESTORE", line 408
> RMAN-10031: ORA-19624 occurred during call to
> DBMS_BACKUP_RESTORE.BACKUPPIECECREATE
> 
> Recovery Manager complete.
> 
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



--
Diane Meeker           ladydi AT virginia DOT edu    
University of Virginia        434-924-4182



--__--__--

Message: 9
Date: Wed, 11 Jul 2001 14:13:49 -0400
From: Tricia A Novak <tricia.novak AT bms DOT com>
To: veritas-bu AT mailman.eng.auburn DOT edu
Organization: Bristol-Myers Squibb
Subject: [Veritas-bu] NBU 3.4 auth.conf file

This is a multi-part message in MIME format.
--------------AB8870414BA7DDA828F38F33
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit

Does anyone know how to set up the auth.conf file so you can give
a group of users rights to some icons using the java gui, but not
all?  I'm running NBU 3.4 on an HP 11.00, trying to configure
they Administration client on an NT server and I want to give the
NT admins rights to just certain icons.

Thanks

--------------AB8870414BA7DDA828F38F33
Content-Type: text/x-vcard; charset=us-ascii;
 name="tricia.novak.vcf"
Content-Transfer-Encoding: 7bit
Content-Description: Card for Tricia A Novak
Content-Disposition: attachment;
 filename="tricia.novak.vcf"

begin:vcard 
n:Novak;Trish
tel;work:609-818-5135
x-mozilla-html:FALSE
org:Data Recovery Services
adr:;;;;;;
version:2.1
email;internet:tricia.novak AT bms DOT com
title:Data Recovery Analyst
fn:Trish Novak
end:vcard

--------------AB8870414BA7DDA828F38F33--


--__--__--

Message: 10
From: Brian_Drager AT Vanguard DOT com
To: veritas-bu AT mailman.eng.auburn DOT edu
Date: Wed, 11 Jul 2001 14:14:46 -0400
Subject: [Veritas-bu] Windows 2000 Clustering

Does NetBackup 3.4 support virtual Server names for backup? How are
other people
backing up cluster servers?

Thanks



--__--__--

Message: 11
From: "Diane M. Meeker" <ladydi AT virginia DOT edu>
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] NBU 3.4 auth.conf file
Date: Wed, 11 Jul 2001 02:33:20 -0400 (Eastern Daylight Time)


Yes,

auth.conf can be set up with something like

userid ADMIN=(options)  

Where options are ...

 AM  - Activity Monitor
 BPM - Backup Policy Management
 JBP - Backup, Archive, and Restore
 DM  - Device Monitor
 MM  - Media Management
 REP - Reports
 SUM - Storage Unit Management

example:

jim ADMIN=DM+MM ...etc.
  

> Date: Wed, 11 Jul 2001 14:13:49 -0400
> From: Tricia A Novak <tricia.novak AT bms DOT com>
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Subject: [Veritas-bu] NBU 3.4 auth.conf file
> 
> Does anyone know how to set up the auth.conf file so you can give
> a group of users rights to some icons using the java gui, but not
> all?  I'm running NBU 3.4 on an HP 11.00, trying to configure
> they Administration client on an NT server and I want to give the
> NT admins rights to just certain icons.
> 
> Thanks



--
Diane Meeker           ladydi AT virginia DOT edu    
University of Virginia        434-924-4182



--__--__--

Message: 12
From: "O'Shea, Don" <Don.OShea AT emergis DOT com>
To: "'Brian_Drager AT vanguard DOT com'" <Brian_Drager AT vanguard DOT com>,
        veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] Windows 2000 Clustering
Date: Wed, 11 Jul 2001 14:39:14 -0400

This message is in MIME format. Since your mail reader does not
understand
this format, some or all of this message may not be legible.

------_=_NextPart_001_01C10A38.CBC2D316
Content-Type: text/plain;
        charset="iso-8859-1"

I was just looking to address this issue also. I had just started
reading
about it in the Netbackup 3.4 administration guide. Unfortunatelly I
can't
tell you the exact page number as I left the manual where I had to
configure
Netbackup. I believe it is somewhere around page 600 or higher. If I get
it
working I will let you know but it probably won't be till some time
tomorrow.

Don O'Shea
NT Support
BCE Emergis Inc.
(905)707-4000 Ext. 3765
Fax: (905) 707-4329
mailto:don.oshea AT emergis DOT com


-----Original Message-----
From: Brian_Drager AT vanguard DOT com [mailto:Brian_Drager AT vanguard DOT com]
Sent: July 11, 2001 2:15 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Windows 2000 Clustering


Does NetBackup 3.4 support virtual Server names for backup? How are
other
people
backing up cluster servers?

Thanks


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

------_=_NextPart_001_01C10A38.CBC2D316
Content-Type: text/html;
        charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2//EN">
<HTML>
<HEAD>
<META HTTP-EQUIV=3D"Content-Type" CONTENT=3D"text/html; =
charset=3Diso-8859-1">
<META NAME=3D"Generator" CONTENT=3D"MS Exchange Server version =
5.5.2650.12">
<TITLE>RE: [Veritas-bu] Windows 2000 Clustering</TITLE>
</HEAD>
<BODY>

<P><FONT SIZE=3D2>I was just looking to address this issue also. I had =
just started reading about it in the Netbackup 3.4 administration =
guide. Unfortunatelly I can't tell you the exact page number as I left =
the manual where I had to configure Netbackup. I believe it is =
somewhere around page 600 or higher. If I get it working I will let you
=
know but it probably won't be till some time tomorrow.</FONT></P>

<P><FONT SIZE=3D2>Don O'Shea</FONT>
<BR><FONT SIZE=3D2>NT Support</FONT>
<BR><FONT SIZE=3D2>BCE Emergis Inc.</FONT>
<BR><FONT SIZE=3D2>(905)707-4000 Ext. 3765</FONT>
<BR><FONT SIZE=3D2>Fax: (905) 707-4329</FONT>
<BR><FONT SIZE=3D2><A =
HREF=3D"mailto:don.oshea AT emergis DOT com">mailto:don.oshea AT emergis DOT 
com</A></
=
FONT>
</P>
<BR>

<P><FONT SIZE=3D2>-----Original Message-----</FONT>
<BR><FONT SIZE=3D2>From: Brian_Drager AT vanguard DOT com [<A =
HREF=3D"mailto:Brian_Drager AT vanguard DOT com">mailto:[email protected]
=
om</A>]</FONT>
<BR><FONT SIZE=3D2>Sent: July 11, 2001 2:15 PM</FONT>
<BR><FONT SIZE=3D2>To: veritas-bu AT mailman.eng.auburn DOT edu</FONT>
<BR><FONT SIZE=3D2>Subject: [Veritas-bu] Windows 2000 Clustering</FONT>
</P>
<BR>

<P><FONT SIZE=3D2>Does NetBackup 3.4 support virtual Server names for =
backup? How are other people</FONT>
<BR><FONT SIZE=3D2>backing up cluster servers?</FONT>
</P>

<P><FONT SIZE=3D2>Thanks</FONT>
</P>
<BR>

<P><FONT =
SIZE=3D2>_______________________________________________</FONT>
<BR><FONT SIZE=3D2>Veritas-bu maillist&nbsp; -&nbsp; =
Veritas-bu AT mailman.eng.auburn DOT edu</FONT>
<BR><FONT SIZE=3D2><A =
HREF=3D"http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu"; =
TARGET=3D"_blank">http://mailman.eng.auburn.edu/mailman/listinfo/veritas
=
-bu</A></FONT>
</P>

</BODY>
</HTML>
------_=_NextPart_001_01C10A38.CBC2D316--


--__--__--

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


End of Veritas-bu Digest