Date: Thu, 1 Mar 2001 16:15:03 -0800
What is the host name of the master.

Let's say it's hostname is master and it's private name is master-B

So on the client you would need to add to it's sever list master-B

On the master the client name should be OC70-B, also in the masters hosts,
or in it's DNS server.

Lastly on the client set the REQUIRED_INTERFACE setting to OC70-B

This is in the configuration GUI accessible through a NT Administrative
client, or I think you could put it in the registry under
HKEY_LOCAL_MACHINE\Software\VERITAS\Current Config\Config

That should do it, but I would load the admin client on one of my desktops,
set it up as a SERVER = on the master, restart the daemons, and then try it.

Bob

-----Original Message-----
From: Conlon, Thomas E (Tom), SITS [mailto:conlont AT att DOT com]
Sent: Thursday, March 01, 2001 3:31 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] bpclntcmd -self failing in multi-homed environment


Help!

        I am trying to get a Win NT NetBackup 3.2 client (master server is
on Solaris 7) with OTM loaded and the SQL db agent to work in a dual-homed
NIC configuration.  The main NIC is connected to our WAN with one additional
virtual IP addy, and the secondary NIC is connected to our SAN.  
        
        The hostname is "OC70", and the alias we are using for DNS reverse
lookup (Lucent QIP DNS 5.2) is "OC70-B".  I have an entry in hosts aliasing
the private SAN IP addy as OC70-B, a pre-cached LMHOSTS entry with the same
info, as well as a static WINS entry with the same info.  

        Bpclntcmd -self still reports the hostname of OC70 for all 3
interfaces.  The best I can come up with is that this a bad port from UNIX
with the gethostbyname function improperly implemented into winsock.  Any
ideas?  Thank you very much.

-tc

Thomas Conlon
AT&T Solutions
Global Networks 
Service Management Center
429 Ridge Rd.
Dayton, NJ 08810-1323

vox:    (732) 392-5349
fax:    (732) 392-3197
cell:   (732) 310-5330
beep:   (888) 858-7243  pin 112916

conlont AT att DOT com

 <<Conlon, Thomas E (Tom), SITS.vcf>> 



<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] bpclntcmd -self failing in multi-homed environme nt, Bob Bakh bbakh <=