Veritas-bu

Summary: [Veritas-bu] Any ideas as to what to do for a code 14?

2000-11-03 16:05:50
Subject: Summary: [Veritas-bu] Any ideas as to what to do for a code 14?
From: John_Wang AT enron DOT net John_Wang AT enron DOT net
Date: Fri, 3 Nov 2000 15:05:50 -0600
Hello

The problem turned out to be the client NIC card having somehow switched to half
duplex by itself.   The network team determined that the switch was receiving a
large number of runts from the port and knew that this tended to happen if the
NIC plugged into the port was not operating at the same settings as the port on
the switch which was set to full duplex.    The server team is scheduling
downtime to change the interface settings.

Regards,
John I Wang
Sr. Systems Engineer
Steverson Information Professionals

---
Enron Broadband Services
Enron Building 1472c
ph (713) 345-4291
fax (713) 646-8063





<Prev in Thread] Current Thread [Next in Thread>
  • Summary: [Veritas-bu] Any ideas as to what to do for a code 14?, John_Wang <=