Veritas-bu

[Veritas-bu] NBU 3.2 &bpend_notify

2000-08-01 14:19:30
Subject: [Veritas-bu] NBU 3.2 &bpend_notify
From: White, Steve D - CNF White.Steve AT cnf DOT com
Date: Tue, 1 Aug 2000 11:19:30 -0700
Are you trying to use the multi-stream option for NBU?  If so, then each
successful stream will run bpend_notify thus your database will be started
after the first successful backup.  If you're going to try and use
multi-streaming with database backups, you need to do some extra careful
coding in your start and end scripts.

Steve White
CNF AdTech Center
Enterprise Support Group
1717 NW 21st Ave.
Portland, OR  97209
Office:  (503) 450-2733
Fax:  (503) 450-3629
Cell Phone: (503) 329-4686
E-mail:  White.Steve AT cnf DOT com

 -----Original Message-----
From:   mookie [mailto:mookie AT ameritech DOT net] 
Sent:   Tuesday, August 01, 2000 5:59 AM
To:     veritas-bu AT mailman.eng.auburn DOT edu
Subject:        [Veritas-bu] NBU 3.2 &bpend_notify

Good morning all,

I'm trying to use bpstart_notify & bpend_notify to perform a cold backup
of oracle with multi-streaming on HP-UX 11.0.  A problem occurs with
bpend_notify where oracle is started after the first filesystem backup
is completed rather than after the last.  Can anyone offer any insight
or suggested solutions to this?

TIA,

Dave

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu