Re: [Networker] Jukebox control port using persistent names
2012-10-25 18:32:31
On 25/10/12 19:48, Yaron Zabary wrote:
> That's the relevant part from the res file. Just shutdown Networker
> and edit the res file to point at the right by-id device.
>
> application key:;
> application name:;
> auto clean: Yes;
> auto media management: No;
> autodetect id: <OVERLANDNEO Series 0636 at SCSI Bus 3 Target 1 LUN 1>;
> available slots: 1-499;
> bar code reader: Yes;
> cleaning delay: 60;
> cleaning slots: 500-500;
> comment:;
> control port: /dev/tape/by-id/scsi-200900de794120009;
There's no need to shutdown NetWorker or edit res files. The control
port is a field you can modify.
|
|
|