If all save sets on a media should have the same retention policy, volretent = 
retention date of the last save set.

Just check out:     mminfo -q "volume=<name>" -r volretent

Then change the retention of an early save set to a later date:         nsrmm 
-e <date> -S <ssid>

Then use the mminfo command to verify the new volretent time.


(20) characters for the full savetime is probably too short. And showing the 
'partial' time does not make sense.
If you want to see the complete time, set your size to 25 characters, then 
decrease and find the limit.

+----------------------------------------------------------------------