Look at document <NetWorker Data Domain Deduplication Devices 7.6 SP2
Integration Guide.pdf> and appendix <Upgrading to
NetWorker 7.6 SP2>
On Fri, May 13, 2011 at 2:38 PM, Kenneth Larsen <kel AT steria DOT dk> wrote:
> Hi everybody
>
> Networker 7.6.2 on windows
> Datadomain 580g and 690g
>
> Before the upgrade to Networker 7.6.2, I could use the Device Wizard to
> configure new Data Domain Boost devices. After the upgrade however I cant
> browse the datadomain anymore, and all the devices I have created there
> are not visible... The device wiard starts up, but only the datadomain
> device name is visible in the select folder structure.
> I am able to create the new device manually, but would be nice to have the
> wizard working too.
>
> I am loath to have to empty my datadomain and reconfigure it, but any
> ideas or anybody seen similar ?
>
> **************************************************
> Med venlig hilsen / Regards
> Kenneth Larsen
> System Konsulent
>
> Steria A/S
> Tonsbakken 16-18
> 2740 Skovlunde
> Mobile: +45 2630 6261
> email: kel AT steria DOT dk
> www.steria.dk
> **************************************************
>
> To sign off this list, send email to listserv AT listserv.temple DOT edu and
> type "signoff networker" in the body of the email. Please write to
> networker-request AT listserv.temple DOT edu if you have any problems with
> this list. You can access the archives at
> http://listserv.temple.edu/archives/networker.html or
> via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
>
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems with this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|