Networker

Re: [Networker] Recover can't find volume after "scanner -m"?

2008-04-30 17:34:43
Subject: Re: [Networker] Recover can't find volume after "scanner -m"?
From: Tim Mooney <Tim.Mooney AT NDSU DOT EDU>
To: NETWORKER AT LISTSERV.TEMPLE DOT EDU
Date: Wed, 30 Apr 2008 16:29:20 -0500
In regard to: Re: [Networker] Recover can't find volume after "scanner...:

C:\PHA Scripts>mminfo -a -r barcode | wc -l
847

C:\PHA Scripts>mminfo -a -r barcode | sort | uniq | wc -l
491

Now, that's strange ....

That does seem pretty odd.  I would definitely look into that, probably
start with something like

  mminfo -a -r 'barcode,volume,volid' | sort

(sort without the uniq, so you can see what barcodes might map to multiple
volumes or volume ids).  That may be the source of your problem, or it
might be a red herring.

Tim
--
Tim Mooney                                        Tim.Mooney AT ndsu DOT edu
Information Technology Services                   (701) 231-1076 (Voice)
Room 242-J6, IACC Building                        (701) 231-8541 (Fax)
North Dakota State University, Fargo, ND 58105-5164

To sign off this list, send email to listserv AT listserv.temple DOT edu and type 
"signoff networker" in the body of the email. Please write to networker-request 
AT listserv.temple DOT edu if you have any problems with this list. You can access the 
archives at http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER

<Prev in Thread] Current Thread [Next in Thread>