Re: [Networker] ADIC Scalar i500 cleaning notification and "MOVE MEDIUM" errors
2007-07-07 11:12:16
On Jul 7, 2007, at 9:58 AM, Paul Robertson wrote:
Folks,
We're running nw_7_3_2_jumbo.Build.11 on Solaris 10 with an ADIC
Scalar i500 library shared with a second storage node.
Over the past few months, we've experienced several occasions where
the Networker server loses the ability to manipulate tapes in the
library. Typically, the error message sequence is as follows:
I don't use ADIC hardware, but I saw similar behavior on my Sony
PetaSite when I allowed it to do automatic tape drive cleanings. The
tape library didn't notify NetWorker when it was actually cleaning a
tape drive, so sometimes, NetWorker would attempt to use a tape drive
that was in the process of being cleaned, which caused problems.
After I configured NetWorker to do auto tape drive cleanings and
configured the tape library not to do auto cleaning, the problem
disappeared. You might try the same thing if you are using your
Scalar i500's auto cleaning feature.