Bacula-users

Re: [Bacula-users] Problems using vchanger

2012-12-14 08:19:17
Subject: Re: [Bacula-users] Problems using vchanger
From: Josh Fisher <jfisher AT pvct DOT com>
To: bacula-users AT lists.sourceforge DOT net
Date: Fri, 14 Dec 2012 08:16:22 -0500
On 12/14/2012 6:29 AM, Pedro Bordin Hoffmann wrote:
> Hello!
>
> Im using vchanger to try to simulate a tape library on a HP RDX, and 
> Im getting some erros...
>
> Like, the tape is mounted Ok in server, but when bacula goes alone to 
> run, I got some erros:
>
> 14-Dez 04:57 bacula..com.br-d JobId 854: Start Backup JobId 854, 
> Job=RH_Sexta.2012-12-14_04.00.01_19
> 14-Dez 04:57 bacula..com.br-d JobId 854: Using Device 
> "usb-changer-drive-0"
> 14-Dez 04:57 bacula..com.br-s JobId 854: No slot defined in catalog 
> (slot=0) for Volume "c1_0009_0001" on "usb-changer-drive-0" 
> (/var/lib/bacula/c1/0/drive0).
> 14-Dez 04:57 bacula..com.br-s JobId 854: Cartridge change or "update 
> slots" may be required.
> 14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume 
> "c1_0009_0001" not on device "usb-changer-drive-0" 
> (/var/lib/bacula/c1/0/drive0).
> 14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0001" 
> in Error in Catalog.
> 14-Dez 04:57 bacula..com.br-s JobId 854: 3307 Issuing autochanger 
> "unload slot 1, drive 0" command.
> 14-Dez 04:57 bacula..com.br-s JobId 854: No slot defined in catalog 
> (slot=0) for Volume "c1_0009_0002" on "usb-changer-drive-0" 
> (/var/lib/bacula/c1/0/drive0).
>
> 14-Dez 04:57 bacula..com.br-s JobId 854: Cartridge change or "update 
> slots" may be required.
> 14-Dez 04:57 bacula..com.br-s JobId 854: 3301 Issuing autochanger 
> "loaded? drive 0" command.
> 14-Dez 04:57 bacula..com.br-s JobId 854: 3302 Autochanger "loaded? 
> drive 0", result: nothing loaded.
> 14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume 
> "c1_0009_0002" not on device "usb-changer-drive-0" 
> (/var/lib/bacula/c1/0/drive0).
> 14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0002" 
> in Error in Catalog.
> 14-Dez 04:57 bacula..com.br-s JobId 854: 3301 Issuing autochanger 
> "loaded? drive 0" command.
> 14-Dez 04:57 bacula..com.br-s JobId 854: 3302 Autochanger "loaded? 
> drive 0", result: nothing loaded.
> 14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume 
> "c1_0009_0002" not on device "usb-changer-drive-0" 
> (/var/lib/bacula/c1/0/drive0).
> 14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0002" 
> in Error in Catalog.
> 14-Dez 04:57 bacula..com.br-s JobId 854: Warning: mount.c:217 Open 
> device "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0) Volume 
> "c1_0009_0002" failed: ERR=dev.c:568 Could not open: 
> /var/lib/bacula/c1/0/drive0, ERR=Arquivo ou diretório não encontrado
>
>
>
> Has anyone know what is going on here?

It looks like the changer and Bacula disagree on which tapes are 
currently in which slots. The 'update slots' command tells Bacula to 
query the changer for the current info. Bacula then stores that info in 
its database and expects the changer slots to remain unchanged. So, 
every time you do anything to the changer that causes its slots to 
change, like swap in another drive, it is necessary to inform Bacula by 
issuing a 'update slots' command in bconsole.


------------------------------------------------------------------------------
LogMeIn Rescue: Anywhere, Anytime Remote support for IT. Free Trial
Remotely access PCs and mobile devices and provide instant support
Improve your efficiency, and focus on delivering more value-add services
Discover what IT Professionals Know. Rescue delivers
http://p.sf.net/sfu/logmein_12329d2d
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users