Im using vchanger to try to simulate a tape library on a HP RDX, and Im getting some erros...
Like, the tape is mounted Ok in server, but when bacula goes alone to run, I got some erros:
14-Dez 04:57 bacula..com.br-d JobId 854: Start Backup JobId 854, Job=RH_Sexta.2012-12-14_04.00.01_19
14-Dez 04:57 bacula..com.br-d JobId 854: Using Device "usb-changer-drive-0"
14-Dez 04:57 bacula..com.br-s JobId 854: No slot defined in catalog (slot=0) for Volume "c1_0009_0001" on "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0).
14-Dez 04:57 bacula..com.br-s JobId 854: Cartridge change or "update slots" may be required.
14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume "c1_0009_0001" not on device "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0).
14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0001" in Error in Catalog.
14-Dez 04:57 bacula..com.br-s JobId 854: 3307 Issuing autochanger "unload slot 1, drive 0" command.
14-Dez 04:57 bacula..com.br-s JobId 854: No slot defined in catalog (slot=0) for Volume "c1_0009_0002" on "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0).
14-Dez 04:57 bacula..com.br-s JobId 854: Cartridge change or "update slots" may be required.
14-Dez 04:57 bacula..com.br-s JobId 854: 3301 Issuing autochanger "loaded? drive 0" command.
14-Dez 04:57 bacula..com.br-s JobId 854: 3302 Autochanger "loaded? drive 0", result: nothing loaded.
14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume "c1_0009_0002" not on device "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0).
14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0002" in Error in Catalog.
14-Dez 04:57 bacula..com.br-s JobId 854: 3301 Issuing autochanger "loaded? drive 0" command.
14-Dez 04:57 bacula..com.br-s JobId 854: 3302 Autochanger "loaded? drive 0", result: nothing loaded.
14-Dez 04:57 bacula..com.br-s JobId 854: Warning: Volume "c1_0009_0002" not on device "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0).
14-Dez 04:57 bacula..com.br-s JobId 854: Marking Volume "c1_0009_0002" in Error in Catalog.
14-Dez 04:57 bacula..com.br-s JobId 854: Warning: mount.c:217 Open device "usb-changer-drive-0" (/var/lib/bacula/c1/0/drive0) Volume "c1_0009_0002" failed: ERR=dev.c:568 Could not open: /var/lib/bacula/c1/0/drive0, ERR=Arquivo ou diretório não encontrado
Has anyone know what is going on here?
--