Hi,
I have not had our TS3310 long and I am still in the process of setting up and
testing with TSM. I have an issues where I get a T038 Drite Tape Alert 9 -
Write Protect, often when a tape is used (but not all tapes). TSM is happy and
does not complain, and it seems (not yet tested 100%) that the tapes are being
written to, so it is just the tape library giving the message.
I would like to know why and how to stop it/fix it?
BTW: The tapes 'tabs' are set in the rw position!
Any suggestions welcome.
Thanks
Ben
The full report is
========================================
SR Serial Number: A0C0150A10
SR Problem Summary: T038 - Drive Tape Alert 9 - Write Protected
SR Error Code: 38
SR Severity: High
Fault code generic :0
Fault code specific :13
Element type generic:UDS-3 Media
Element Location :0,1
Tape Drive Serial Number :1068012322
VolSer : B00001L5
Logical Library : library_a
Fault description:All Tape Alerts posted-> 09
========================================
3576-MTL - SN xxxxxxxxxxx - High Priority Problem
REASON FOR AUTOMATED E-MAIL
RAS Status Changed
LibraryTime: 01/21/2011 06:26:12
TICKET SUMMARY
Ticket# 21
Name: T038 - Drive Tape Alert 9 - Write Protected
Description: The tape drive was requested to write to a write-protected tape.
Priority: High
State: UnOpened
Created: Date: Fri Jan 21 06:26:12
Type: Interactive Diagnostics Required
ATTACHMENTS
Library snapshot:
REPAIR AND TROUBLESHOOTING INSTRUCTIONS
DR014generic
TICKET DETAILS
Fault code generic :0
Fault code specific :13
Element type generic:UDS-3 Media
Element Location :0,1
Tape Drive Serial Number :xxxxxxxxxxxxxx
VolSer : B00001L5
Logical Library : library_a
Fault description:All Tape Alerts posted-> 09
NETWORK DATA
Hostname: d06adts3
DHCP: disabled
IP Address: xxxxxxxxxxxxxxx
Netmask: xxxxxxxxxxxx
Gateway: xxxxxxxxxxxxx
Ethernet MAC: xxxxxxxxxxxxxxxxx
Speed: 1000Mb/s
Link: yes
LIBRARY VERSION
587G.GS003
DRIVES
Chassis:0, Sled Bay:2
Vendor: IBM
Model: ULT3580-TD5
P-SN: xxxxxxxxxxxxx
L-SN: xxxxxxxxxxxxx
FW Rev: A6S0
Status: Ready
Chassis:0, Sled Bay:1
Vendor: IBM
Model: ULT3580-TD5
P-SN: xxxxxxxxxxxxx
L-SN: xxxxxxxxxxxxx
FW Rev: A6S0
Status: Ready
Chassis:-1, Sled Bay:4
Vendor: IBM
Model: ULT3580-TD5
P-SN: xxxxxxxxxxxxx
L-SN: xxxxxxxxxxxxx
FW Rev: A6S0
Status: Ready
Chassis:-1, Sled Bay:3
Vendor: IBM
Model: ULT3580-TD5
P-SN: xxxxxxxxxxxxx
L-SN: xxxxxxxxxxxxx
FW Rev: A6S0
Status: Ready
Chassis:-1, Sled Bay:2
Vendor: UNKNOWN
Model:
P-SN:
L-SN: xxxxxxxxxxxxx
FW Rev:
Status: NotReady
Chassis:-1, Sled Bay:1
Vendor: UNKNOWN
Model:
P-SN:
L-SN: xxxxxxxxxxxxx
FW Rev:
Status: NotReady
+----------------------------------------------------------------------
|This was sent by benjamin_shade AT uk.ibm DOT com via Backup Central.