Re: [ADSM-L] IBM3592-E06 resp. TS1130
2010-11-05 10:18:18
I am using format=drive in my devclass, no problem reading E05 tapes.
A filling E05 tape will be written in E05 format, a new one in E06 format.
But how to see which tape is written in E05 ? ( the written capacity is
some hint, but on filling its difficult).
Am 11/5/10 2:51 PM, schrieb Richard Sims:
Would not your prior use of 3592-E05 have been with devclass Format 3592-2, and
new use of 3592-E06 be with devclass Format 3592-3, in a recent TSM
version/level supporting that specification?
Richard Sims
--
--
Matthias Feyerabend | M.Feyerabend AT gsi DOT de
GSI Helmholtzzentrum für Schwerionenforschung GmbH | phone +49-6159-71-2519
Planckstr. 1 | privat +49-6151-718781
D-64291 Darmstadt | fax +49-6159-71-2519
www.gsi.de
Gesellschaft mit beschränkter Haftung
Sitz der Gesellschaft: Darmstadt
Handelsregister: Amtsgericht Darmstadt, HRB 1528
Geschäftsführung: Professor Dr. Dr. h.c. Horst Stöcker,
Dr. Hartmut Eickhoff
Vorsitzende des Aufsichtsrates: Dr. Beatrix Vierkorn-Rudolph
Stellvertreter: Ministerialdirigent Dr. Rolf Bernhardt
|
|
|