ADSM-L

Re: [ADSM-L] How to checkin tapes from I/O-station?

2007-11-21 03:35:44
Subject: Re: [ADSM-L] How to checkin tapes from I/O-station?
From: "Baker, Jane" <Jane.Baker AT CLARKS DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Wed, 21 Nov 2007 08:34:38 -0000
 
The checkin will work with search=bulk but it will have prompted you and you 
needed to reply, q req will show prompts and if you then issue reply (number) 
it will go, alternatively you can put waitt=0 on the end to stop it prompting 
(presuming you have TSM 5.3).

HTH.


 

-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of 
Bjørn Nachtwey
Sent: 20 November 2007 15:48
To: ADSM-L AT VM.MARIST DOT EDU
Subject: [ADSM-L] How to checkin tapes from I/O-station?

Hi,

this is perhaps a newbee question, but:

how do i check new tapes into a 3584 library using the I/O-station?

what i want to do:
i'm running two tape libraries, and because the year ends soon, some
money has left for buying new tapes to fill both library.

unfortunately a certain time ago some tapes belonging (due to their
labeling) to library B have been inserted into library A.

now i remove this tapes from A and want to replace them by the new ones.
well, in library A there are only a few scratch tapes, so I cannot empty
all the wrong tapes and remove them all at once.
instead I empty just 10 of them and then remove them by checking out to
the I/O-station.
actually I want to check-in and label the right-labeled inserted in the
I/O-station.

what i already tried:

dsm> checkin libvolume 3584 search=yes checkin=scratch

dsm> label libv 3584 search=yes labels=barcode checkin=scratch
volrange=ABW500,ABW509

dsm> label libv 3584 search=bulk labels=barcode checkin=scratch
volrange=ABW500,ABW509

thanks

Bjørn

-- 
########################################################################
Dipl.-Ing. Bjørn Nachtwey
Technische Universität Carolo-Wilhelmina zu Braunschweig
Gauss-IT-Zentrum (GITZ) -- Abteilung Server
Hans-Sommer-Straße 56,  38106 Braunschweig
Telephon: +49 (0)531 / 391 - 5535
TeleFax:  +49 (0)531 / 391 - 5549
http://www.tu-braunschweig.de/it
mailto: b.nachtwey AT tu-bs DOT de
mailto: c0034031 AT tu-bs DOT de
########################################################################
PGP-Schluessel:
http://www-public.tu-bs.de:8080/~nachtwey/bjoern_nachtwey.asc
PGP-Fingerprint:
B472 526A A903 4AEB 9269 EC0B 9CDE 7465 CE87
########################################################################


Please check that this email is addressed to you. If not, you should delete it 
immediately as its contents may be confidential and its disclosure, copying or 
distribution unlawful.

C. & J. Clark International Limited takes steps to prevent the transmission of 
electronic viruses but responsibility for screening incoming messages and the 
risk of such transmission lies with the recipient.