ADSM-L

Re: [ADSM-L] schedule to exclude system object

2007-10-19 12:56:05
Subject: Re: [ADSM-L] schedule to exclude system object
From: Larry Clark <lclark01 AT NYCAP.RR DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Fri, 19 Oct 2007 12:55:41 -0400
Have you done a q sched f=d to see how it displays? Does it display with the
double quotes?
I know I have run into this situation doing a def/update sched on AIX

----- Original Message -----
From: "Tim Brown" <tbrown AT CENHUD DOT COM>
To: <ADSM-L AT VM.MARIST DOT EDU>
Sent: Friday, October 19, 2007 12:50 PM
Subject: Re: [ADSM-L] schedule to exclude system object


Have tried various combinations no luck

Tim

----- Original Message -----
From: "Larry Clark" <lclark01 AT NYCAP.RR DOT COM>
To: <ADSM-L AT VM.MARIST DOT EDU>
Sent: Friday, October 19, 2007 11:45 AM
Subject: Re: schedule to exclude system object


looks like you have a problem with the quotes. It is inserted with single
ticks insrtead of quotes. Just a guess. do a q sched f=d to verify.

If so you may have to do something like:

update schedule nt nt_daily_fs option='"-domain=-systemobject'"

single tick then quote to preserve the double quote.


should be "-domain=sys
----- Original Message -----
From: "Tim Brown" <tbrown AT CENHUD DOT COM>
To: <ADSM-L AT VM.MARIST DOT EDU>
Sent: Friday, October 19, 2007 11:33 AM
Subject: [ADSM-L] schedule to exclude system object


Created schedule to exclude system object as described in client admin
for
windows guide

 update schedule nt nt_daily_fs option="-domain=-systemobject"

This is exactly how its coded in the manual

However when client schedule runs I get this error

 ANS1107E Invalid option/value: '-domain=-systemobject'


Tim Brown
Systems Specialist - Project Leader
Central Hudson Gas & Electric
284 South Ave
Poughkeepsie, NY 12601
Email: tbrown AT cenhud DOT com
Phone: 845-486-5643
Fax: 845-486-5921
Cell: 845-235-4255