Re: Restores failing
2006-10-25 09:42:28
Richard Sims wrote:
> Regarding:
>
>> Removable volume 5009L is required for a restore request from session
>> 1444. (SESSION: 1444)
>
> Hello, Skylar -
>
> Whereas a full Query Volume shows a healthy volume, let's now look
> further...
>
> Do 'Query LIBVolume * 5009L'. If that responds with
> ANR2034E QUERY LIBVOLUME: No match found using this criteria.
> it suggests that the volume was checked out of the library.
AFAIK, I haven't checked the volume out at all, but in any case it's
been in the library since I tried the restore.
tsm: SHANTI>q libv * 5009L f=d
Library Name Volume Name Status Owner Last Use Home
Device Cleanings Left Media Type
Element Type
------------ ----------- ---------- ---------- --------- -------
------ -------------- ----------
EMPIRE 5009L Private Data 4,099
> Also, something that should have immediately caught my eye yesterday:
> that volume name is only five characters long, which is odd: I would
> expect it to be six characters, or 8 if the 2-char cartridge type
> appendage is observed. Research your Activity Log and see how that
> cartridge was introduced to TSM, and what has gone on with it.
> Something's not right there.
I checked it in through our I/O port. The volume name comes from our bar
code reader, and it matches the text that's on that volume.
--
-- Skylar Thompson (skylar2 AT u.washington DOT edu)
-- Genome Sciences Department, System Administrator
-- K324, (206)-685-7354
-- University of Washington Medical Center
|
|
|