ADSM-L

waiting for mount point ??

2006-05-11 08:29:19
Subject: waiting for mount point ??
From: "Rees, Chris (E.ON IS UK)" <Chris.Rees AT EON-UK DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Thu, 11 May 2006 13:28:33 +0100
All

I'm a little confused by what I'm seeing here and I'm hoping someone can
shed some light on this..

TSM Server 5.2.4.0
AIX 5.2
Atape 9.6.0.0

We have a shared 3584library with 12 LTO1, 15 LTO2 and 3 LTO3 drives all
fibre attached.
The mountlimits in my devclasses are set as follows

LTO1 12
LTO2 16
LTO3 3

At the moment I clearly have 2 LTO3 drives available with nothing
mounted in them (DRIVE34 and DRIVE35)



3584_SHWD              DRIVE01                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE02                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE03                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE04                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE05                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE06                ULTRIUMC,ULTRIUM     EMPTY
3584_SHWD              DRIVE07                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE08                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE09                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE0A                ULTRIUMC,ULTRIUM     EMPTY
3584_SHWD              DRIVE0B                ULTRIUMC,ULTRIUM     EMPTY
3584_SHWD              DRIVE0C                ULTRIUMC,ULTRIUM
LOADED                 CARSINGTON
3584_SHWD              DRIVE11                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE12                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE13                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE14                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE15                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE16                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE21                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE22                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE23                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE24                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE25                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE26                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE31                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE32                ULTRIUM2C,ULTRIU     EMPTY
3584_SHWD              DRIVE33                ULTRIUM2C,ULTRIU
LOADED                 CARSINGTON
3584_SHWD              DRIVE34                ULTRIUM3C,ULTRIU     EMPTY
3584_SHWD              DRIVE35                ULTRIUM3C,ULTRIU     EMPTY
3584_SHWD              DRIVE36                ULTRIUM3C,ULTRIU
LOADED                 CARSINGTON



I have a space reclamation process running for one of my LTO3 storage
pools but its now been waiting for a mount point for too long. This is
an onsite storage pool.
The drives are online, I've checked the paths and they are correct and
online, there are no mount errors in actlog.

Process     Process Description      Status
  Number
--------     --------------------
-------------------------------------------------
   3,380     Space Reclamation        Volume SH0885L3 (storage pool
                                       RMM_VDC_DATA_PRIM_LTO3), Moved
Files: 0, Moved
                                       Bytes: 0, Unreadable Files: 0,
Unreadable Bytes:
                                       0. Current Physical File (bytes):
                                       23,989,533
Waiting for mount point in device
                                       class ULTRIUM3 (2225 seconds).


So has anyone got any ideas... let me know if you need more
information..

Thanks

Chris


___________________________ Disclaimer Notice ____________________
This message and any attachments are confidential and should only
be read by those to whom they are addressed. If you are not the
intended recipient, please contact us, delete the message from your
computer and destroy any copies. Any distribution or copying without
our prior permission is prohibited.

Internet communications are not always secure and therefore the
E.ON Group does not accept legal responsibility for this message.
The recipient is responsible for verifying its authenticity before
acting on the contents. Any views or opinions presented are solely
those of the author and do not necessarily
represent those of the E.ON Group.

E.ON UK plc, Westwood Way, Westwood Business Park,
Coventry, CV4 8LG.
Registered in England & Wales No. 2366970

E.ON UK Trading Ltd, Westwood Way, Westwood Business Park,
Coventry, CV4 8LG
Registered in England & Wales No. 4178314

E.ON UK Trading Ltd is authorised and regulated by the Financial Services
Authority to carry out energy investment activities.

Telephone +44 (0) 2476 42 4000
Fax +44 (0) 2476 42 5432

<Prev in Thread] Current Thread [Next in Thread>